IBM SG24-6526-00 manual You must journal the following files at a minimum

Models: SG24-6526-00

1 184
Download 184 pages 3.35 Kb
Page 97
Image 97
You must journal the following files at a minimum:

You must journal the following files at a minimum:

￿All physical files in the OSLVCF3 library (except for files named XAPnn if they were there)

￿The PMP02 and PMP09 files in the OSLD1F3 library

￿The AGP00, AGP10, and AGP20 files in the OSLD2F3 library

To journal these files with no ASP, follow these steps:

Note: The following commands are sample commands only. You may vary them as required.

1.Sign on as QSECOFR.

2.Create a new library for the journal receiver and journal such as OSLF3:

CRTLIB LIB(OSLF3) TEXT('OSL journal library')

3.Create a journal receiver:

CRTJRNRCV JRNRCV(OSLF3/OSL0001) THRESHOLD(50000) TEXT('System21 journal receiver.')

4.Create a journal:

CRTJRN JRN(OSLF3/OSL) JRNRCV(OSLF3/OSL0001) MNGRCV(*SYSTEM) DLTRCV(*YES) TEXT('System21 journal')

To journal the files using an ASP, follow these steps:

1.Create a separate library for the journal receiver:

CRTLIB LIB(OSLF3R) TEXT('OSL journal receiver library')

2.Create a journal receiver:

CRTJRNRCV JRNRCV(OSLF3R/OSL0001) ASP(2) THRESHOLD(50000) TEXT('System21 journal receiver.')

3.Create the journal as shown in step 4 in the previous sequence of steps.

To journal a single file, such as ADDRESS, use the following command:

STRJRNPF FILE(OSLVCF3/ADDRESS) JRN(OSLF3/OSL) OMTJRNE(*OPNCLO)

To journal multiple files within a library, complete the following steps.

Note: This is the recommended method.

1.Start the Programming Development Manager (PDM):

STRPDM

2.Select option 9 (Work with user-defined options).

Chapter 4. Installing and setting up vendor.connect 85