JVC Model 200 service manual Lamp Failed to light /LAMPLITB not Low for

Models: Model 200

1 140
Download 140 pages 61.68 Kb
Page 126
Image 126

 

 

 

 

 

Chapter 5---Troubleshooting

 

 

4.6

 

“VA PCA Not OK”

 

/VA_OK is High (BAD).

 

 

 

 

 

 

 

 

 

 

 

 

 

4.7

 

“VP PCA Missing”

 

“No Slave Ack” status on first poll of VP.

 

 

 

 

 

 

 

 

 

4.8

 

“VP PCA Not OK”

 

VP_OK is High (BAD)

 

 

 

 

 

 

 

 

 

4.9

 

“RTG PCA Missing”

 

“No Slave Ack” status on first poll of RTG

 

 

 

 

 

 

 

 

 

4.10

 

“RTG PCA Not OK”

 

RTG_OK is High (BAD)

 

 

 

 

 

 

 

 

 

4.14

 

“Lamp Startup”

 

Lamp Failed to light (/LAMP_LIT_B not Low for 3

 

 

 

 

 

 

seconds out of 20 seconds.)

 

 

4.15

 

“Low Voltage PS”

 

Low Voltage PS failed (/LV_OK_B is High).

 

 

 

 

 

 

 

 

 

4.16

 

“High Voltage PS”

 

High Voltage PS failed (/HV_OK_B is High).

 

 

 

 

 

 

 

 

 

4.17

 

“VIC1 Board Not OK”

 

/VIC_OK is High (BAD) on VIC Slot 1.

 

 

 

 

 

 

 

 

 

4.18

 

“VIC 2 Board Not Ok”

 

/VIC_OK is High (BAD) on VIC Slot 2

 

 

 

 

 

 

 

 

 

4.19

 

“VIC3 Board Not OK”

 

/VIC_OK is High (BAD) on VIC Slot 3

 

 

 

 

 

 

 

 

 

4.20

 

“VIC1 Invalid Type”

 

Software does not support VIC_ID in Slot 1

 

 

 

 

 

 

 

 

 

4.21

 

“VIC2 Invalid Type”

 

Software does not support VIC_ID in Slot 2

 

 

 

 

 

 

 

 

 

4.22

 

“VIC3 Invalid Type”

 

Software does not support VIC_ID in Slot 3

 

 

 

 

 

 

 

 

 

4.23

 

“Shutters Missing”

 

One or more shutters not installed (BAD)

 

 

 

 

 

 

 

 

 

4.24

 

"Lamp Start Not On"

 

/LAMP_OK is high, lamp module not installed, jumper

 

 

 

 

 

 

missing, ALPS bad.

 

 

Most Category 6 error codes indicate RS232 communication errors and apply to Switchers only.

 

 

 

 

 

 

 

 

 

6.1

 

“Sync Timeout”

 

No Header found in data stream - possible baud rate

 

 

 

 

 

 

error.

 

 

6.2

 

“No Char Repeat”

 

Expected data characters to be repeated - failed.

 

 

 

 

 

 

 

 

 

6.3

 

“Invalid Format”

 

Data not in Extron or JVC Switcher format.

 

 

 

 

 

 

 

 

 

7.1

 

“Write Len Error”

 

Ansi Output to RS232 port was interrupted -

 

 

 

 

 

 

incomplete.

 

 

8.1

 

“VIC Slot is empty”

 

User has selected a Channel - VIC is not present.

 

 

 

 

 

 

 

 

 

8.2

 

“VIC Type Changed”

 

User has selected a Channel - VIC type has changed.

 

 

 

 

 

 

User may have swapped a VIC into an incorrect slot.

 

 

8.3

 

“Interpol Blocked”

 

Software process error - Interpolation Process not

 

 

 

 

 

 

allowed to run by higher priority processes.

 

 

9.1

 

“Quad Dec Not Init”

 

HW: Quad Decoder failed Startup Sequence.

 

 

 

 

 

 

 

 

 

10.1

 

“Shutter Stat BAD”

 

One or more shutters reading wrong status.

 

 

 

 

 

 

 

 

One other error may appear on the monitor screen with the statement “Assertion

Failed” (only if the PC is connected to Port A). This is a very rare but serious

Model 200 Service Manual

5-5

Page 126
Image 126
JVC Model 200 service manual Lamp Failed to light /LAMPLITB not Low for