Chapter 2---System Description
+24VDC
+80VDC
/LV_OK:
Operation:
The main power is filtered via the input filter to prevent radiation from escaping back to the power line. From the line filter, AC power is fed into the Low Voltage Power Supply module where AC is rectified, filtered, and compensated for power factor correction.
The +5.1V Standby is on whenever AC power is connected to the projector and the circuit breaker on the rear panel is in the On position. The +24V standby power for the fans turns on when the /FAN_ENA signal is received from the System Controller (this turns off in
Arc Lamp Power Supply (ALPS)
P71
AC | 1 |
INPUT | 3 |
| 5 |
P72
To P9 on | 1 | |
2 | ||
Backplane | ||
| 3 |
4
5
6
Line | LAMP_OUT | |
LAMP_RET | ||
Earth | ||
| ||
Neutral |
|
GNDLAMP_OK
/LAMP_LIT GND /LAMP_OK
/LAMP_ENA
COVER_ON GND
P74
1To Lamp
2Module, J74
P73
1To Lamp
2Module, J74
Figure 2-4. Arc Lamp Power Supply, Block Diagram
Main Functions:
•Provides ignition power to turn the Xenon Arc Lamp ON.
•Provides steady state power to maintain the lamp ON. Inputs:
The Arc Lamp Power Supply receives AC input power directly from the power source. The input range is from
/LAMP_ENA: From System Controller. Turns on the ALPS.
Model 200 Service Manual |