| Chapter | |
|
|
|
| |
| IIC_DATA | IIC data line. Serial line for synchronous data transfer of the following |
| |
|
| data between Video Processor Board and SCB board. I=Input, |
| |
|
| O=Output. |
| |
|
| I | BEAM CURRENT |
|
|
| I | OK DETECT |
|
|
| O | RED_CONT |
|
|
| O | GRN_CONT |
|
|
| O | BLU_CONT |
|
|
| O | BRIGHTNESS |
|
|
| O | RED_G2 |
|
|
| O | BLU_G2 |
|
|
| O | GRN_G2 |
|
|
| O | WHT_BOOST |
|
|
| O | BLK_BOOST |
|
|
|
|
| |
|
|
|
| |
| OUTPUTS | DESCRIPTION |
| |
|
|
|
| |
| OVERLAY | Overlay control signal |
| |
| /IIC_INT | IIC interrupt line. |
| |
|
|
|
| |
| RED_OVER | Red signal of |
| |
|
|
|
| |
| GRN_OVER | Similar to RED_OVER |
| |
|
|
|
| |
| BLU_OVER | Similar to RED_OVER |
| |
|
|
|
| |
| BLU_THRES | Threshold correction information for blue. Real time data at 0 volt to |
| |
|
| 1 volt. |
| |
| GRN_THRES | Similar to BLU_THRES |
| |
|
|
|
| |
| RED_THRES | Similar to BLU_THRES |
| |
|
|
|
| |
| BLU_SENS | Sensitivity correction information for BLU. Real time data at O volt to |
| |
|
| 1 volt. |
| |
| GRN_SENS | Similar to BLU_SENS |
| |
|
|
|
| |
| RED_SENS | Similar to BLU_SENS |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Raster Timing Generator |
|
| INPUTS | DESCRIPTION |
| |
|
|
|
| |
| SOURCE_ | This signal indicates a new source (or valid). A high indicates a valid |
| |
| VALID | stable signal and low indicates change in input signal. |
| |
| ODD_FIELD | Square wave with 50 % duty cycle which is low during the odd field |
| |
|
| of an interlace signal. This signal is high for noninterlaced signals. |
| |
| 280_CLK | Square wave signal, 50 % duty cycle, 280 times the frequency of |
| |
|
| horizontal sync. This clock is synchronized to the horizontal sync. |
|
Model 200 Service Manual |