NCR S26 Table A-1 -Watt Power Supply Input Requirements, Input Nominal Frequency Variations

Models: S26

1 220
Download 220 pages 9.55 Kb
Page 110
Image 110

Input Requirements

Input Requirements

The following represent the input requirements of the 420-watt power supply:

Maximum waveform harmonic distortion shall be less than 5%. The power supply must operate above frequency with both 100~120/200~240 VRMS input voltage ranges.

The power supply must operate over both voltage ranges with an outside switch.

The table below shows the 420-watt power supply input requirements.

Table A-1. 420-Watt Power Supply Input Requirements

Input

Nominal Frequency

Frequency

Frequency

 

Variations

 

 

 

 

50 Hz

47 Hz ~ 53 Hz

 

60 Hz

57 Hz ~ 63 Hz

Input Voltage

Nominal Voltage

Variation Range

 

100 ~ 120 VRMS

90 ~ 132 VRMS

 

200 ~ 240 VRMS

180 ~ 264 VRMS

Input Current

Maximum Input Current

Measuring

 

 

Range

 

8 A

90 ~ 132 VRMS

 

4 A

180 ~ 264 VRMS

Inrush Current

The power supply inrush current shall be less than the ratings of

 

its critical components (including the fuse, rectifiers, and the

 

surge-limiting device) for all conditions of line voltage.

Efficiency

63% minimum (measuring at maximum load, applying nominal

 

line)

 

 

 

 

A-2

420-Watt Power Supply Requirements

Page 110
Image 110
NCR S26 manual Table A-1 -Watt Power Supply Input Requirements, Input Nominal Frequency Variations