Sample RAID Configuration
Sample RAID Configuration
A RAID configuration might consist of the following:
∙Pentium Pro 200 MHz Processor w/ECC Mem Support
∙128 MB System Memory
∙PCI Ethernet Adapter (SMC8432BTA)
∙PCI Token Ring Adapter (Olicom
∙PCI RAID Adapter (Mylex)
∙Four 4 GB SCSI wide hard drives connected to the Mylex RAID controller
∙SCSI
Installing the Hardware
To install the hardware, follow these steps:
1.Combine the hot plug backplane.
2.Connect a wide SCSI cable between the Mylex PCI RAID adapter and the top SCSI connector on the hot plug backplane. (If a wide SCSI cable is connected between the system board and the top SCSI connector on the hot plug backplane, remove this cable.)
3.Strap the
4.Strap the four 4 GB wide drives as SCSI IDs 0, 1, 2, 3. Plug them into the hot plug backplane in drive bays 1, 2, 3, and 4 (top four
5.Install the memory SIMMs in banks one and two on the system baseboard (installed in groups of two SIMMs).
6.Install the PCI RAID Adapter in PCI slot 1 (topmost PCI slot).
7.Install the PCI Token Ring Adapter in PCI slot 2.
NCR S26 Hot Plug Server User Guide |