NCR S26 manual Sample RAID Configuration, Installing the Hardware

Models: S26

1 220
Download 220 pages 9.55 Kb
Page 131
Image 131

Sample RAID Configuration

Sample RAID Configuration

A RAID configuration might consist of the following:

Pentium Pro 200 MHz Processor w/ECC Mem Support

128 MB System Memory

PCI Ethernet Adapter (SMC8432BTA)

PCI Token Ring Adapter (Olicom OC-3136)

PCI RAID Adapter (Mylex)

Four 4 GB SCSI wide hard drives connected to the Mylex RAID controller

SCSI CD-ROM drive connected to the onboard AIC-7880 SCSI controller

Installing the Hardware

To install the hardware, follow these steps:

1.Combine the hot plug backplane.

2.Connect a wide SCSI cable between the Mylex PCI RAID adapter and the top SCSI connector on the hot plug backplane. (If a wide SCSI cable is connected between the system board and the top SCSI connector on the hot plug backplane, remove this cable.)

3.Strap the CD-ROM drive as SCSI ID 3. Insert it into the top, front 5.25- inch drive bay. Connect the power cable and the narrow SCSI cable to the CD-ROM drive.

4.Strap the four 4 GB wide drives as SCSI IDs 0, 1, 2, 3. Plug them into the hot plug backplane in drive bays 1, 2, 3, and 4 (top four hot-plug drive bays).

5.Install the memory SIMMs in banks one and two on the system baseboard (installed in groups of two SIMMs).

6.Install the PCI RAID Adapter in PCI slot 1 (topmost PCI slot).

7.Install the PCI Token Ring Adapter in PCI slot 2.

NCR S26 Hot Plug Server User Guide