Sample Standard Configuration
To configure the SCSI adapters and drivers, if connected to an Adaptec SCSI adapter, follow these steps:
1. Press Ctrl + A when the following displays:
Adaptec
(Refer to the Adaptec SCSI documentation for additional information about these settings).
2.Select SCSI Disk Utilities. Observe that the 2 GB disk drive and the CD- ROM drive are displayed with the correct information. If a
3.Select Configure/View Host Adapter Settings and set the parameters as follows:
SCSI Bus Interface Definitions |
|
Host Adapter SCSI ID | [7] |
SCSI Parity Checking | [Enabled] |
Host Adapter SCSI Term | [Low OFF/High ON] |
Boot Device Options: |
|
Boot Target ID | [0] |
Boot LUN Number | [0] |
4. Select SCSI Device Configuration and set the parameters as follows:
SCSI Device ID (tab to desired device) |
|
Initiate Sync Negotiation | [yes] |
Maximum Sync Transfer Rate* | [40] |
Enable Disconnection | [yes] |
Initiate Wide Negotiation | [yes] |
Send Start Unit Command | [yes] |
*Note: See note in step 6.
NCR S26 Hot Plug Server User Guide |