13 – Command Reference Set Config Threshold

Notes

The switch will down a port if an alarm condition is not cleared within three

 

consecutive sampling windows (by default 30 seconds). Reset the port to bring it

 

back online. An alarm is cleared when the threshold monitoring detects that the

 

error rate has fallen below the falling trigger.

 

 

 

Examples

The following is an example of the Set Config Threshold command:

 

 

SANbox #> admin start

 

 

 

 

 

SANbox (admin) #> config edit

 

 

 

 

 

SANbox (admin-config) #> set config threshold

 

 

 

 

A list of attributes with formatting and current values will follow.

 

 

Enter a new value or simply press the ENTER key to accept the current

value.

 

If you wish to terminate this process before reaching the end of the list

 

press 'q' or 'Q' and the ENTER

key to do so.

 

 

 

 

ThresholdMonitoringEnabled

(True / False)

 

[False

]

 

CRCErrorsMonitoringEnabled

(True / False)

 

[True

]

 

RisingTrigger

(decimal value,

1-1000)

[25

]

 

FallingTrigger

(decimal value,

0-1000)

[1

]

 

SampleWindow

(decimal value,

1-1000 sec) [10

]

 

DecodeErrorsMonitoringEnabled

(True / False)

 

[True

]

 

RisingTrigger

(decimal value,

1-1000)

[25

]

 

FallingTrigger

(decimal value,

0-1000)

[0

]

 

SampleWindow

(decimal value,

1-1000 sec) [10

]

 

ISLMonitoringEnabled

(True / False)

 

[True

]

 

RisingTrigger

(decimal value,

1-1000)

[2

]

 

FallingTrigger

(decimal value,

0-1000)

[0

]

 

SampleWindow

(decimal value,

1-1000 sec) [10

]

 

LoginMonitoringEnabled

(True / False)

 

[True

]

 

RisingTrigger

(decimal value,

1-1000)

[5

]

 

FallingTrigger

(decimal value,

0-1000)

[1

]

 

SampleWindow

(decimal value,

1-1000 sec) [10

]

 

LogoutMonitoringEnabled

(True / False)

 

[True

]

 

RisingTrigger

(decimal value,

1-1000)

[5

]

 

FallingTrigger

(decimal value,

0-1000)

[1

]

 

SampleWindow

(decimal value,

1-1000 sec) [10

]

 

LOSMonitoringEnabled

(True / False)

 

[True

]

 

RisingTrigger

(decimal value,

1-1000)

[100

]

 

FallingTrigger

(decimal value,

0-1000)

[5

]

 

SampleWindow

(decimal value,

1-1000 sec) [10

]

Finished configuring attributes.

This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect.

To discard this configuration use the config cancel command.

59183-01 A

13-73

Page 203
Image 203
Q-Logic 5602 Error rate has fallen below the falling trigger, Following is an example of the Set Config Threshold command