13 – Command Reference
Set Config Zoning
13-74 59183-01 A
S
Set Config Zoning
Configures the zoning database. The changes you make with this command are
not retained when you reset or power cycle the switch unless you save them using
the Config Save command.
Authority Admin session and a Config Edit session
Syntax set config zoning
Initiates an editing session in which to change the zoning database configuration.
The system displays each parameter one line at a time and prompts you for a
value. For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Table 13-19. Zoning Configuration Parameters
Parameter Description
InteropAutoSave Enables (True) or disables (False) the saving of changes to active
zone set in the switch’s non-volatile zoning database.The default
is True.
Disabling the Autosave parameter can be useful to prevent the
propagation of zoning information when experimenting with differ-
ent zoning schemes. However, leaving the InteropAutoSave
parameter disabled can disrupt device configurations should a
switch have to be reset. For this reason, the InteropAutoSave
parameter should be enabled in a production environment.
DefaultZone Enables (True) or disables (False) communication among
ports/devices that are not defined in the active zone set. The
default is True.
DiscardInactive Enables (True) or disables (False) the discarding of all inactive
zone sets from that zoning database. Inactive zone sets are all
zone sets except the active zone set. The default is False.