13 – Command Reference Set Config Zoning
S
Set Config Zoning
Configures the zoning database. The changes you make with this command are not retained when you reset or power cycle the switch unless you save them using the Config Save command.
Authority Admin session and a Config Edit session
Syntax set config zoning
Initiates an editing session in which to change the zoning database configuration. The system displays each parameter one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.
Table 13-19. Zoning Configuration Parameters
Parameter | Description |
|
|
InteropAutoSave | Enables (True) or disables (False) the saving of changes to active |
| zone set in the switch’s |
| is True. |
| Disabling the Autosave parameter can be useful to prevent the |
| propagation of zoning information when experimenting with differ- |
| ent zoning schemes. However, leaving the InteropAutoSave |
| parameter disabled can disrupt device configurations should a |
| switch have to be reset. For this reason, the InteropAutoSave |
| parameter should be enabled in a production environment. |
DefaultZone | Enables (True) or disables (False) communication among |
| ports/devices that are not defined in the active zone set. The |
| default is True. |
DiscardInactive | Enables (True) or disables (False) the discarding of all inactive |
| zone sets from that zoning database. Inactive zone sets are all |
| zone sets except the active zone set. The default is False. |
|
|
|