13 – Command Reference Show Switch
S
Table 13-27.  Switch Operational Parameters (Continued)
Parameter | Description  | 
  | 
  | 
PrincipalSwitchRole  | Principal switch status. True indicates that this  | 
  | switch is the principal switch.  | 
BoardTemp (1) - Degrees Celsius  | Internal switch temperature at circuit board sensor  | 
  | 1.  | 
SwitchDiagnosticsStatus  | Results of the   | 
SwitchTemperatureStatus  | Switch temperature status: normal, warning, fail-  | 
  | ure.  | 
  | 
  | 
Examples The following is an example of the Show Switch command:
SANbox #> show switch  | 
  | 
Switch Information  | 
  | 
  | |
SymbolicName  | SANbox  | 
SwitchWWN  | 10:00:00:c0:dd:00:bc:56  | 
BootVersion  | |
CreditPool  | 0  | 
DomainID  | 19 (0x13)  | 
FirstPortAddress  | 130000  | 
FlashSize - MBytes  | 128  | 
LogFilterLevel  | Critical  | 
MaxPorts  | 20  | 
NumberOfSwitchResets  | 15  | 
ReasonForLastReset  | PowerUp  | 
ActiveImageVersion - build date  | Vx.x.x.0 (day month date time year)  | 
PendingImageVersion - build date  | Vx.x.x.0 (day month date time year)  | 
ActiveConfiguration  | default  | 
AdminState  | Online  | 
AdminModeActive  | False  | 
Beacon  | Off  | 
OperationalState  | Online  | 
PrincipalSwitchRole  | False  | 
BoardTemp (1) - Degrees Celsius  | 32  | 
SwitchDiagnosticsStatus  | Passed  | 
SwitchTemperatureStatus  | Normal  | 
 | 
 |