13 – Command Reference Test Port

Notes Table 13-28describes the port test parameters.

Table 13-28. Port Test Parameters

Parameter

Description

 

 

LoopCount

Number of frames sent

FrameSize

Number of bytes in each test frame

DataPattern

Pattern in the payload

StopOnError

Stops the test when an error occurs (True).

 

Otherwise, the test continues to comple-

 

tion.

LoopForever

Restarts the test after completion and con-

 

tinues until you cancel it (True). Otherwise,

 

the test ends normally after completion.

 

 

To cancel a port test that is in progress, enter the Test Cancel Port command.

To display the status of the most recent port test or port test in progress, enter the Test Status Port command.