13 – Command Reference
Show Port
13-130 59183-01 A
S
DecodeError Number of decode errors detected
DiagFaultCode Fault code from the most recent Power-on self test
DiagStatus Status from the most recent Power-on self test
EpConnects Number of times an E_Port connected through ISL negotia-
tion.
EpConnState E_Port connection status
EpIsoReason E_Port isolation reason
FBusy Number of times the switch sent a F_BSY because Class 2
frame could not be delivered within ED_TOV time. Number of
class 2 and class 3 fabric busy (F_BSY) frames generated by
this port in response to incoming frames. This usually indi-
cates a busy condition on the fabric or N_Port that is prevent-
ing delivery of this frame.
Flowerrors Number of frames received there were no available credits.
FReject Number of frames from devices that were rejected.
InvalidCRC Invalid CRC detected.
InvalidDestAddr Invalid destination address detected.
IOStreamGuard I/O StreamGuard status
Link Failures Number of optical link failures detected by this port. A link fail-
ure is a loss of synchronization or a loss of signal while not in
the offline state. A loss of signal causes the switch to attempt
to re-establish the link. If the link is not re-established, a link
failure is counted. A link reset is performed after a link failure.
LinkSpeed Port transmission speed
LinkState Port activity status
LIP_AL_PD_ALPS Number of F7, AL_PS LIPs, or AL_PD (vendor specific)
resets, performed.
LIP_F7_AL_PS This LIP is used to reinitialize the loop. An L_Port, identified by
AL_PS, may have noticed a performance degradation and is
trying to restore the loop.
LIP_F8_AL_PS This LIP denotes a loop failure detected by the L_Port identi-
fied by AL_PS.
Table 13-26. Show Port Parameters (Continued)
Entry Description