13 – Command Reference
Set Log
13-78 59183-01 A
S
level [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events
for the specified components or ports. [filter] can be one of the following values:
Critical
Monitors critical events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no
action. This is the default severity level.
Warn
Monitors warning and critical events. The warning level describes events
that are generally not disruptive to the administration or operation of the
fabric, but are more important than the informative level events.
Info
Monitors informative, warning, and critical events. The informative level
describes routine events associated with a normal fabric.
None
Monitors none of the severity levels.
port [port_list]
Specifies one or more ports to monitor for events. Choose one of the following
values:
[port_list]
Specifies the port or ports to monitor. [port_list] can be a set of port numbers
and ranges delimited by spaces. For example, [0 2 10-15] specifies ports 0,
2, 10, 11, 12, 13, 14, and 15.
All
Specifies all ports.
None
Disables monitoring on all ports.
restore
Restores and saves the port, component, and level settings to the default values.
NOTE: Logging events at the Info severity level can deplete switch
resources because of the high volume of events.