13 – Command Reference Set Log

S

level [filter]

Specifies the severity level given by [filter] to use in monitoring and logging events for the specified components or ports. [filter] can be one of the following values:

Critical

Monitors critical events. The critical level describes events that are generally disruptive to the administration or operation of the fabric, but require no action. This is the default severity level.

Warn

Monitors warning and critical events. The warning level describes events that are generally not disruptive to the administration or operation of the fabric, but are more important than the informative level events.

Info

Monitors informative, warning, and critical events. The informative level describes routine events associated with a normal fabric.

NOTE: Logging events at the Info severity level can deplete switch resources because of the high volume of events.

None

Monitors none of the severity levels.

port [port_list]

Specifies one or more ports to monitor for events. Choose one of the following values:

[port_list]

Specifies the port or ports to monitor. [port_list] can be a set of port numbers and ranges delimited by spaces. For example, [0 2 10-15] specifies ports 0, 2, 10, 11, 12, 13, 14, and 15.

All

Specifies all ports.

None

Disables monitoring on all ports.

restore

Restores and saves the port, component, and level settings to the default values.

13-78

59183-01 A

Page 208
Image 208
Q-Logic 5602 Level filter, Monitors none of the severity levels, Specifies all ports, Disables monitoring on all ports