A

13 – Command Reference Show Media

Table 13-25. Transceiver Information (Continued)

Information Type

Description

 

 

Temp

Temperature in degrees Celsius.

Voltage

Supply voltage in Volts. The range is 0–6.55.

Tx Bias

Transmitter laster bias current in milliamps. The range is

 

0–655.

Tx Power

Transmitter coupled output power in milliWatts. The range is

 

0–6.55.

Rx Power

Received optical power in milliWatts. The range is 0–6.55.

Value

Measured value.

Status

State associated with the measured value:

 

„ Normal: Value is in the normal operating range.

 

„ HighAlarm: Value exceeds the high alarm threshold.

 

„ HighWarning: Value exceeds the high warning threshold.

 

„ LowWarning: Value is less than the low warning threshold.

 

„ LowAlarm: Value is less than the low alarm threshold.

HighAlarm

Vendor specified threshold above which an alarm is issued.

HighWarning

Vendor specified threshold above which a warning is issued.

LowWarning

Vendor specified threshold below which a warning is issued.

LowAlarm

Vendor specified threshold below which an alarm is issued.

 

 

59183-01 A

13-119

Page 249
Image 249