The Object Dictionary

 

 

 

 

Error Code

The table below lists the error codes and their meanings:

Meanings

 

 

 

Error

Diagnostics

Meaning

 

 

code

 

 

 

 

 

 

 

0000H

ERROR_RESET_OR_NO_ERROR

Clearing of one, or all, errors

 

 

 

 

 

1000H

GENERIC_ERROR

Internal communication error

 

 

 

 

 

2100H

CURRENT_DEVICE_INPUT_SIDE

Sensor power supply short-circuit

 

 

 

(M12 connector)

 

 

 

 

 

2320H

SHORT_CIRCUIT_AT_OUTPUTS

Output short-circuit

 

 

 

 

 

3100H

MAINS_VOLTAGE

Sensor/splitter box voltage is lower

 

 

 

than approximately 12V

 

 

 

 

 

3120H

INPUT_VOLTAGE_TOO_LOW

Splitter box has detected under-

 

 

 

voltage in the sensor

 

 

 

 

 

3310H

OUTPUT_VOLTAGE_TOO_HIGH

Splitter box has detected over-

 

 

 

voltage in the actuator

 

 

 

 

 

3320H

OUTPUT_VOLTAGE_TOO_LOW

The splitter box has detected under-

 

 

 

voltage in the actuator (see note)

 

 

 

 

 

6101H

SOFTWARE_RX_QUEUE_OVERRUN

The receive buffer has exceeded its

 

 

 

internal memory capacity

 

 

 

 

 

6102H

SOFTWARE_TX_QUEUE_OVERRUN

The transmit buffer has exceeded its

 

 

 

internal memory capacity

 

 

 

 

 

8100H

COMMUNICATION

Synchronization, transmit/receive

 

 

 

error counter > 96

 

 

 

 

 

8120H

CAN_IN_ERROR_PASSIVE_MODE

CAN controller interrupted

 

 

 

 

 

8130H

LIFE_GUARD_ERROR

Node-Guarding error

 

 

 

 

 

8140H

BUS_OFF

The CAN frame error counter has

 

 

 

exceeded its capacity

 

 

 

 

 

9000H

EXTERNAL_ERROR

Detection of wire cut

 

 

 

 

 

F000H

ADDITIONAL_FUNCTION

Actuator voltage is lower than

 

 

 

approximately 12V

 

 

 

 

Note: When there are no set outputs, there are no associated messages. The state of the DO POWER LED is not significant. CANopen Objects Diagnostics, p. 127