Application-Specific Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Object

Sub-

Bit

Description

 

 

 

index

 

 

 

 

 

 

 

 

 

 

6102H

1

Bit 0

Channel 0 input polarity if channel 0 configured for input

 

 

 

 

 

Not assigned if channel 0 configured for output

 

 

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

 

 

Bit 7

Channel 7 input polarity if channel 7 configured for input

 

 

 

 

 

Not assigned if channel 7 configured for output

 

 

 

 

 

 

 

 

 

 

Bit 8

Channel 10 input polarity if channel 10 configured for input

 

 

 

 

 

Channel 10 diagnostics input polarity if channel 10 configured

 

 

 

 

 

for diagnostics input

 

 

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

 

 

Bit 15

Channel 17 input polarity if channel 17 configured for input

 

 

 

 

 

Channel 17 diagnostics input reading if channel 17 configured

 

 

 

 

 

for diagnostics input

 

 

 

 

 

 

 

 

6103H

1

Bit 0

Channel 0 input masking if channel 0 configured for input

 

 

 

 

 

Not assigned if channel 0 configured for output

 

 

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

 

 

Bit 7

Channel 7 input masking if channel 7 configured for input

 

 

 

 

 

Not assigned if channel 7 configured for output

 

 

 

 

 

 

 

 

 

 

Bit 8

Channel 10 input masking if channel 10 configured for input

 

 

 

 

 

Channel 10 diagnostics input masking if channel 10

 

 

 

 

 

configured for diagnostics input

 

 

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

 

 

Bit 15

Channel 17 input masking if channel 17 configured for input

 

 

 

 

 

￿Channel 17 diagnostics input masking if channel 17

 

 

 

 

 

configured for diagnostics input

 

 

 

 

 

 

 

Note: All the objects are 16-bit word tables except for 2000H and 6000H. Sub-index 1 of object 6000H corresponds to the 6100H (pin 4) object's least

￿significant byte

Object 2000H, read by byte, concerns channels 10 to 17 only (pin 2).

1606218 02 08/2006

93

Page 93
Image 93
Schneider Electric IP67 manual Channel 17 diagnostics input masking if channel