Application-Specific Functions

 

 

 

 

 

 

 

 

 

 

 

Object

Sub-

Bit

Description

 

 

index

 

 

 

 

 

 

 

 

6307H

1

Bit 0

Channel 0 output fallback value if channel 0 configured for

 

 

 

 

output

 

 

 

 

Not assigned if channel 0 configured for input

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 7

Channel 7 output fallback value if channel 7 configured for

 

 

 

 

￿output

 

 

 

 

Not assigned if channel 7 configured for input

 

 

 

 

 

 

 

 

Bit 8

Not assigned

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 15

Not assigned

 

 

 

 

 

 

6308H

1

Bit 0

Channel 0 output masking if channel 0 configured for output

 

 

 

 

Not assigned if channel 0 configured for input

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 7

Channel 7 output masking if channel 7 configured for output

 

 

 

 

￿Not assigned if channel 7 configured for input

 

 

 

 

 

 

 

 

Bit 8

Not assigned

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 15

Not assigned

 

 

 

 

 

Note: All the objects are 16-bit word tables except for 6200H.

For object 6200H:

Sub-index 1 corresponds to the 6300H (pin 4) object's least significant byte

￿Sub-index 2 corresponds to the 6300H (pin 2) object's most significant byte