The Object Dictionary

Object 3000H: Manufacturer Specific Diagnostic

Description

This object provides information on the status of the Advantys FTB CANopen splitter

 

 

box.

 

 

 

 

 

Characteristics

 

 

 

 

 

 

The characteristics of this object are outlined in the following table:

 

 

 

 

 

 

 

 

Sub-

Description

Data type

Default value

Access

PDO Mapping

Backed up

index

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Sub-index number

UNSIGNED8

7

ro

no

no

 

 

 

 

 

 

 

1

Common diagnostics (8

UNSIGNED8

-

ro

yes

no

 

least significant MSR bits,

 

 

 

 

 

 

object 1002H)

 

 

 

 

 

 

 

 

 

 

 

 

2

Sensor short-circuit (0-7

UNSIGNED8

-

ro

yes

no

 

connectors)

 

 

 

 

 

 

 

 

 

 

 

 

3

Actuator stopped

UNSIGNED8

-

ro

yes

no

 

(channels 00 - 07)

 

 

 

 

 

 

 

 

 

 

 

 

4

Actuator stopped

UNSIGNED8

-

ro

yes

no

 

(channels 10 - 17)

 

 

 

 

 

 

 

 

 

 

 

 

5

Actuator overload

UNSIGNED8

-

ro

yes

no

 

(channels 00-07)

 

 

 

 

 

 

 

 

 

 

 

 

6

Actuator overload

UNSIGNED8

-

ro

yes

no

 

(channels 10-17)

 

 

 

 

 

 

 

 

 

 

 

 

7

Diagnostics inputs

UNSIGNED8

-

ro

yes

no

 

 

 

 

 

 

 

 

Note: The sub-indexes are only present in the 3000H object if the Advantys FTB splitter box offers the corresponding functions.