The Object Dictionary

Object 1805H: 2nd Transmit PDO Communication Parameter

Description

 

This object contains the Transmit PDO identifier.

 

 

 

Properties

 

 

 

 

 

 

 

 

The characteristics of this object are outlined in the following table:

 

 

 

 

 

 

 

 

Sub-index

Description

Data type

Default value

Acces

PDO

Backed up

 

 

 

 

 

s

Mapping

 

 

 

 

 

 

 

 

0

Sub-index

UNSIGNED8

05H

ro

no

yes

 

number

 

 

 

 

 

 

 

 

 

 

 

 

1

COB-ID

UNSIGNED32

0000 0280H + Node ID

rw

no

yes

 

 

 

 

 

 

 

2

Transmission

UNSIGNED8

FFH (255 Dec

rw

no

yes

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

3

Inhibit Time

UNSIGNED16

0

rw

no

yes

 

 

 

 

 

 

 

4

Not available

 

 

 

 

 

 

 

 

 

 

 

 

5

Event Timer

UNSIGNED16

0

rw

no

yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 