The Object Dictionary
Object 1001H: Error Register
Description | This object is used by the device to display internal faults. When a fault is detected, | ||
| the corresponding bit is therefore activated. | ||
| The following faults can be displayed: |
| |
|
|
|
|
| Bit | Meaning | Comments |
|
|
|
|
| 0 | Generic error | - |
|
|
|
|
| 1 | Current fault (overload or short- | - |
|
| circuit) |
|
|
|
|
|
| 2 | Voltage fault | - |
|
|
|
|
| 3 | Temperature | Unchecked |
|
|
|
|
| 4 | Communication error | - |
|
|
|
|
| 5 | Reserved | Unchecked |
|
|
|
|
| 6 | Reserved | Unchecked |
|
|
|
|
| 7 | Specific to the manufacturer | Detection of wire cut |
|
|
|
|
|
|
|
|
Characteristics | The characteristics of this object are given in the following FTB splitter box table: | ||||||
|
|
|
|
|
|
| |
Description | Data type | Default value | Access | PDO Mapping | Backed up | ||
|
|
|
|
|
|
|
|
- | - |
| UNSIGNED8 | - | ro | no | no |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
136 | 1606218 02 08/2006 |