List of Advantys FTB 1CN12E04SP0 Splitter Box I/O Objects
List of FTB | The list of input objects for the Advantys FTB 1CN12E04SP0 splitter box is given in | ||||
1CN12E04SP0 | the following table: |
| |||
Input Objects |
|
|
|
| |
Object | Sub- | Bit | Description | ||
| |||||
|
| index |
|
| |
|
|
|
|
| |
| 2000H | 1 | Bit 0 | Choice between the "input" function and the "diagnostics | |
|
|
|
| input" function for channel 10 | |
|
|
|
|
| |
|
|
| ... | ... | |
|
|
|
|
| |
|
|
| Bit 7 | Choice between the "input" function and the "diagnostics | |
|
|
|
| input" function for channel 17 | |
|
|
|
|
| |
| 6000H | 1 | Bit 0 | Reading of channel 0 input | |
|
|
|
|
| |
|
|
| ... | ... | |
|
|
|
|
| |
|
|
| Bit 3 | Reading of channel 3 input | |
|
|
|
|
| |
|
|
| Bit 4 | Not assigned | |
|
|
|
|
| |
|
|
| ... | ... | |
|
|
|
|
| |
|
|
| Bit 7 | Not assigned | |
|
|
|
|
| |
|
| 2 | Bit 8 | Reading of channel 10 input | |
|
|
|
|
| |
|
|
| ... | ... | |
|
|
|
|
| |
|
|
| Bit 15 | Reading of channel 17 input | |
|
|
|
|
| |
| 6100H | 1 | Bit 0 | Reading of channel 0 input | |
|
|
|
|
| |
|
|
| ... | ... | |
|
|
|
|
| |
|
|
| Bit 3 | Reading of channel 3 input | |
|
|
|
|
| |
|
|
| Bit 4 | Not assigned | |
|
|
|
|
| |
|
|
| ... | ... | |
|
|
|
|
| |
|
|
| Bit 7 | Not assigned | |
|
|
|
|
| |
|
|
| Bit 8 | Reading of channel 10 input | |
|
|
|
|
| |
|
|
| ... | ... | |
|
|
|
|
| |
|
|
| Bit 15 | Reading of channel 17 input | |
|
|
|
|
|