Application-Specific Functions

List of Advantys FTB 1CN16EP0 and FTB 1CN16EM0 Splitter Box I/O Objects

List of

The list of input objects for the Advantys FTB 1CN16EP0 and FTB 1CN16EM0

FTB 1CN16EP0

splitter boxes is given in the following table:

and

 

 

 

 

Object

Sub-

Bit

Description

FTB 1CN16EM0

 

index

 

 

Input Objects

 

 

 

 

 

 

 

2000H

1

Bit 0

Choice between the "input" function and the "diagnostics input"

 

 

 

 

 

function for channel 10

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 7

Choice between the "input" function and the "diagnostics input"

 

 

 

 

function for channel 17

 

 

 

 

 

 

6000H

1

Bit 0

Reading of channel 0 input

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 7

Reading of channel 7 input

 

 

 

 

 

 

 

2

Bit 0

Reading of channel 10 input

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 7

Reading of channel 17 input

 

 

 

 

 

 

6100H

1

Bit 0

Reading of channel 0 input

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 15

Reading of channel 17 input

 

 

 

 

 

 

6102H

1

Bit 0

Polarity of channel 0

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 15

Polarity of channel 17

 

 

 

 

 

 

6103H

1

Bit 0

Channel 0 masking

 

 

 

 

 

 

 

 

...

...

 

 

 

 

 

 

 

 

Bit 15

Channel 17 masking

 

 

 

 

 

Note: All the objects are 16-bit word tables except for 2000H and 6000H. Sub-index 1 of object 6000H corresponds to the 6100H (pin 4) object's least significant byte

Sub-index 2 of object 6000H corresponds to the 6300H (pin 2) object's most

￿significant byte.

Object 2000H, read by byte, concerns channels 10 to 17 only (pin 2).