CANopen Network Interface

Configuring the Address and Transmission Speed

Method

Follow the steps below:

 

 

 

 

 

 

Step

Action

 

 

 

 

 

 

1

Switch off the power supply to the splitter box.

 

 

 

 

 

 

2

Unscrew both screws on the transparent cover.

 

 

 

 

 

 

3

Set the communication speed.

 

 

 

 

 

 

4

Set the splitter box address.

 

 

 

 

 

 

5

Screw the transparent cover back on.

 

 

 

 

 

 

6

Power up the splitter box.

 

 

 

 

 

 

 

 

 

Illustration of the

Rotary Switches

DATA NODE ADDRESS

RATE

X10

X1

9

0

1

9

0

1

9

0

1

 

 

 

8

 

2

8

 

2

8

 

2

7

 

3

7

 

3

7

 

3

6

5

4

6

5

4

6

5

4

 

 

 

 

 

 

1

 

 

 

2

 

 

 

3

Element

Function

1Sets the transmission speed

2Node-ID x 10

3Node-ID x 1

Assignment of The CANopen address is configured using two specially designed rotary switches. the Address on Addresses can be configured from 1 to 99. Address zero (0) cannot be used. the Network

Note: When assigning the addresses, ensure that each splitter box is assigned to a single address.

A configured address is registered at power up. It cannot be changed if you do not remove the cover.

46

1606218 02 08/2006

Page 46
Image 46
Schneider Electric IP67 Configuring the Address and Transmission Speed, Illustration Rotary Switches, Data Node Address