Schneider Electric IP67 Object 1010H Store Parameters, Written to the corresponding sub-index

Models: IP67

1 198
Download 198 pages 30.62 Kb
Page 146
Image 146

The Object Dictionary

Object 1010H: Store Parameters

Description

 

This object is used to store the parameters of the splitter box in backed up memory.

Characteristics

 

 

 

 

 

 

The characteristics of this object are outlined in the following table:

 

 

 

 

 

 

 

 

Sub-index

Description

Data type

Default

Acces

PDO

Backed up

 

 

 

 

value

s

Mapping

 

 

 

 

 

 

 

 

0

Sub-index number

UNSIGNED8

4

ro

no

no

 

 

 

 

 

 

 

1

Store all parameters

UNSIGNED32

-

rw

no

no

 

 

 

 

 

 

 

2

Store communication

UNSIGNED32

-

rw

no

no

 

parameters (1000H–

 

 

 

 

 

 

1FFFH)

 

 

 

 

 

 

 

 

 

 

 

 

3

Store standardized

UNSIGNED32

-

rw

no

no

 

application parameters

 

 

 

 

 

 

(6000H–9FFFH)

 

 

 

 

 

 

 

 

 

 

 

 

4

Store manufacturer-

UNSIGNED32

-

rw

no

no

 

specific application

 

 

 

 

 

 

parameters (2000H–

 

 

 

 

 

 

5FFFH)

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

 

 

 

 

 

To save the parameters, the "save" ASCII character string (6576 6173H) must be

written to the corresponding sub-index:

 

Most significant word

Least significant

 

 

 

word

 

 

 

 

 

 

Hex value

65H

76H

61H

73H

 

 

 

 

 

ISO 8859 (ASCII)

e

v

a

s

signature

 

 

 

 

 

 

 

 

 

The read result of a sub-index is always 0000 0001H.

146

1606218 02 08/2006

Page 146
Image 146
Schneider Electric IP67 manual Object 1010H Store Parameters, Written to the corresponding sub-index