Issue 07/04

5 MICROMASTER 420 specifications

Table 5-2

Dimensions, required cooling air flow and tightening torques for power terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frame

 

 

 

 

Dimensions

 

 

 

 

Required cooling air

Tightening torque for

Size

 

 

 

 

 

 

 

 

 

 

flow

 

 

power connections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

W x H x D

 

mm

 

73 173 149

 

l/s

 

4.8

 

 

Nm

 

1.1

 

inch

 

2.87

6.81

5.87

 

CFM

 

10.2

 

 

lbf.in

 

10

 

 

 

 

 

 

 

 

 

 

 

B

 

W x H x D

 

mm

 

149

202

172

 

l/s

 

24

 

 

Nm

 

1.5

 

inch

 

5.87

7.95

6.77

 

CFM

 

51

 

 

lbf.in

 

13.3

 

 

 

 

 

 

 

 

 

 

 

C

 

W x H x D

 

mm

 

185

245

195

 

l/s

 

54.9

 

 

Nm

 

2.25

 

inch

 

7.28

9.65

7.68

 

CFM

 

116.3

 

 

lbf.in

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5-3

Current reduction depending on pulse frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mains voltage

Power (CT)

 

 

 

Output current in A with a switching frequency of:

 

 

 

[kW]

 

4 kHz

 

 

6 kHz

 

8 kHz

10 kHz

12 kHz

 

14 kHz

 

16 kHz

1/3 AC 200 V

 

0.12 to 5.5

Factory setting 16 kHz – no derating necessary

 

 

 

 

 

 

 

3 AC 400 V

 

0.37

 

1.2

 

 

1.2

 

1.2

 

1.2

1.2

 

 

1.2

 

 

1.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.55

 

1.6

 

 

1.6

 

1.6

 

1.6

1.6

 

 

1.6

 

 

1.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.75

 

2.1

 

 

2.1

 

2.1

 

2.1

1.6

 

 

1.6

 

 

1.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1

 

3.0

 

 

3.0

 

2.7

 

2.7

1.6

 

 

1.6

 

 

1.1

 

 

 

1.5

 

4.0

 

 

4.0

 

2.7

 

2.7

1.6

 

 

1.6

 

 

1.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2

 

5.9

 

 

5.9

 

5.1

 

5.1

3.6

 

 

3.6

 

 

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0

 

7.7

 

 

7.7

 

5.1

 

5.1

3.6

 

 

3.6

 

 

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.0

 

10.2

 

10.2

 

6.7

 

6.7

4.8

 

 

4.8

 

 

3.6

 

 

 

5.5

 

13.2

 

13.2

 

13.2

 

13.2

9.6

 

 

9.6

 

 

7.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

 

19.0

 

18.4

 

13.2

 

13.2

9.6

 

 

9.6

 

 

7.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11.0

 

26.0

 

26.0

 

17.9

 

17.9

13.5

 

 

13.5

 

 

10.4

MICROMASTER 420

Operating Instructions

6SE6400-5AA00-0BP0

159

Page 159
Image 159
Siemens 420 manual KHz 10 kHz 12 kHz 14 kHz 16 kHz