3 Functions

Issue 07/04

3.1Parameters

3.1.1Setting / monitoring parameters and parameter attributes

The drive inverter is adapted to the particular application using the appropriate parameters. This means that each parameter is identified by a parameter number, parameter text and specific attributes (e.g. readable, can be written into, BICO attribute, group attribute etc.). Within any one particular drive system, the parameter number is unique. On the other hand, an attribute can be assigned a multiple number of times so that several parameters can have the same attribute.

For MICROMASTER, parameters can be accessed using the following operator units:

BOP (option)

AOP (option)

PC-based commissioning (start-up) tool "Drive Monitor" or "STARTER". These PC-based tools are supplied on the CD-ROM.

The parameter types are the main differentiating feature of the parameters.

 

 

Parameter

 

 

Read (r....)

 

Write/Read (P....)

"normal"

BICO output

"normal"

BICO input

Read parameters

Write-/Read parameters

Fig. 3-1 Parameter types

Setting parameters

Parameters which can be written into and read – "P" parameters

These parameters are activated/de-activated in the individual functions and directly influence the behavior of a function. The value of this parameter is saved in a non- volatile memory (EEPROM) as long as the appropriate option was selected (non- volatile data save). Otherwise, these values are saved in the non-volatile memory (RAM) of the processor, which are lost after power failure or power-off/power-on operations.

Notation:

 

P0927

setting parameter 927

P0748.1

setting parameter 748, bit 01

P0719[1]

setting parameter 719 index 1

P0013[0...19]

setting parameter 13 with 20 indices (indices 0 to 19)

Abbreviated notation

P0013[20] setting parameter 13 with 20 indices (indices 0 to 19)

MICROMASTER 420

Operating Instructions

38

6SE6400-5AA00-0BP0

Page 38
Image 38
Siemens 420 manual Parameters, Setting / monitoring parameters and parameter attributes, Setting parameters, Notation