Siemens 420 manual Digital output Dout, 5.5, Selection of frequency setpoint

Models: 420

1 190
Download 190 pages 14.8 Kb
Page 74
Image 74

3 Functions

Issue 07/04

3.5.5.4Digital output (DOUT)

P0731 =...

P0748 = 0

BI: Function of digital output 1*

52.3

Defines source of digital output 1.

 

 

 

Invert digital output

0

Defines high and low states of relay for a given function.

Common Settings:

 

 

52.0

Drive ready

0

Closed

52.1

Drive ready to run

0

Closed

52.2

Drive running

0

Closed

52.3

Drive fault active

0

Closed

52.4

OFF2 active

1

Closed

52.5

OFF3 active

1

Closed

52.6

Switch on inhibit active

0

Closed

52.7

Drive warning active

0

Closed

DOUT channel Invert DOUTs

0 ... 1

P0748 (0)

BI: Fct. of DOUT 1

 

 

P0731

0

 

(52:3)

1

-1

 

CO/BO: State DOUTs

r0747

r0747.0

COM Kl.10

NO

Kl.11

3.5.5.5

P1000 =...

Selection of frequency setpoint

Selection of frequency setpoint

 

2

0

No main setpoint

 

 

 

1

MOP setpoint

 

 

 

2

Analog setpoint

 

 

 

3

Fixed frequency

 

 

 

4

USS on BOP link

 

 

5

USS on COM link

 

 

6

CB on COM link

 

 

 

 

MOP

 

Sequence control

 

 

 

 

ADC

 

 

 

 

FF

P1000 = 12

Additonal

 

 

 

 

setpoint

 

 

USS

 

Setpoint

Motor

 

BOP link

 

channel

control

 

USS

P1000 = 12

Main

 

 

COM link

 

setpoint

 

 

CB

 

 

 

 

COM link

 

 

 

MICROMASTER 420

Operating Instructions

74

6SE6400-5AA00-0BP0

Page 74
Image 74
Siemens 420 manual Digital output Dout, 5.5, Selection of frequency setpoint