Issue 07/04

3 Functions

Table 3-11 Parameter P0731 (frequently used functions / states)

Parameter value

Significance

52.0

Drive ready

52.1

Drive ready to run

 

 

52.2

Drive running

 

 

52.3

Drive fault active

52.4

OFF2 active

 

 

52.5

OFF3 active

 

 

52.6

Switch-on inhibit active

 

 

52.7

Drive warning active

52.8

Deviation, setpoint / actual value

 

 

52.9

PZD control (Process Data Control)

 

 

52.A

Maximum frequency reached

 

 

52.B

Warning: Motor current limit

52.C

Motor holding brake (MHB) active

 

 

52.D

Motor overload

 

 

52.E

Motor running direction right

52.F

Inverter overload

53.0

DC brake active

 

 

53.1

Act. frequency f_act >= P2167 (f_off)

 

 

53.2

Act. frequency f_act > P1080 (f_min)

53.3

Act. current r0027 >= P2170

 

 

53.6

Act. frequency f_act >= setpoint

 

 

NOTE

A complete list of all of the binary status parameters (refer to "CO/BO" parameters) can be taken from the parameter list.

MICROMASTER 420

Operating Instructions

6SE6400-5AA00-0BP0

91

Page 91
Image 91
Siemens 420 manual Parameter P0731 frequently used functions / states