Siemens 420 manual Reference quantities, Interface 100 %, Parameter Designation Value 100 % Units

Models: 420

1 190
Download 190 pages 14.8 Kb
Page 50
Image 50

3 Functions

Issue 07/04

3.1.3Reference quantities

Parameter range:

P2000 - P2002

When being output or read-in by the drive inverter, physical quantities are normalized or de-normalized. This conversion is made directly by the particular interface using the reference quantities. The normalization / de-normalization is carried-out for the following interfaces:

Table 3-5

Normalized interfaces

 

 

 

 

Interface

 

100 %

Analog input (voltage input)

10 V

 

 

Analog output (current output)

20 mA

 

 

 

USS

 

4000 h

 

 

 

CB

 

4000 h

Further, a normalization is carried-out for a BICO connection if the connector output (CO) represents a physical quantity and the connector input (CI) a normalized (percentage) quantity (e.g. PID controller). A de-normalization is carried-out if the inverse applies.

Reference quantities (normalization quantities) are intended to allow setpoints and actual signals to be represented in a uniform, standard way (normalization / de- normalization of physical quantities such as setpoint and actual frequency). This also applies to permanently set parameters that are assigned the "percentage" units. A value of 100 % corresponds in this case to a process data value PZD of 4000 h (USS or CB) or a current value of 20 mA (analog output) or a voltage value of 10 V (analog input). The following reference parameters and permanently saved reference values are available:

Table 3-6

Normalization functions

 

 

 

 

 

 

 

Parameter

 

Designation

Value (100 % / 4000

Units

 

 

 

h)

 

P2000

 

Reference frequency

P2000

Hz

P2001

 

Reference voltage

P2001

V

 

 

 

 

 

P2002

 

Reference current

P2002

A

 

 

 

 

 

-

 

Reference speed

P2000 * 60 / r0313

RPM

-

 

Reference temperature

100 °C

°C

-

 

Reference energy

100 kWh

kWh

 

 

 

 

 

MICROMASTER 420

Operating Instructions

50

6SE6400-5AA00-0BP0

Page 50
Image 50
Siemens 420 manual Reference quantities, Interface 100 %, Parameter Designation Value 100 % Units