Issue 07/04

3 Functions

The interrelationship between access level P0003 and the grouping P0004 is schematically shown in Fig. 3-3.

User access level P0003 = 1 Standard

2Extended

3Expert

4Service

P0004 = 0

(no filter function) allows direct access to the parameters. For BOP and AOP depending on the selected access level

P0004 = 2, P0003 = 1

Parameters level 1 concerning the inverter unit

P0004 = 2, P0003 = 3

Parameters level 1, 2 and 3 concerning the inverter unit

P0004 = 2

Inverter Unit

P0004 = 2, P0003 = 2

Parameters level 1 and 2 concerning the inverter unit

P0004 = 2, P0003 = 4

Parameters level 1, 2, 3 and 4 concerning the inverter unit

P0004 = 22

P0004 = 2

Inverter Unit

PID Controller

P0200 ... P0299

P0004 = 21

P0003 = 1

P0004 = 3

Alarms, Warnings &

Motor Data

Monitoring

 

P0300 ... P0399

 

P0600 ... P0699

 

 

 

P0003 = 2

P0004 = 20

P0003 = 3

 

Communication

 

P2000 ... P2099

P0003 = 4

 

P0004 = 13

Motor Control

P1300 ... P1799

P0004 = 12

 

 

P0004 = 7

Drive Features

 

 

Commands and

 

 

Digital I/O

P1200 ... P1299

 

 

P0004 = 10

P0004 = 8

P0700 ... P0749

 

 

P0800 ... P0899

 

Setpoint Channel &

Analogue I/O

 

 

Ramp Generator

P0750 ... P0799

 

 

P1000 ... P1199

 

 

Fig. 3-3 Parameter grouping / access

MICROMASTER 420

Operating Instructions

6SE6400-5AA00-0BP0

43

Page 43
Image 43
Siemens 420 manual P0003 =, P0004 =