Siemens 420 manual BOP link interface BOP on BOP link USS on BOP link

Models: 420

1 190
Download 190 pages 14.8 Kb
Page 96
Image 96

3 Functions

Issue 07/04

The BOP, a programming / operator unit (e.g. AOP, PC with DriveMonitor / STARTER) or a programmable control with communications processor can be connected via this BOP link. Data transfer between MICROMASTER and the programming / operator units is realized using the USS protocol via the RS232 interface (point-to-point data coupling). Communications between the BOP and MICROMASTER uses an optimized interface which takes into consideration the somewhat limited resources of the BOP. If the BOP is replaced by an USS unit (PC, AOP), then MICROMASTER automatically identifies the interface of the new unit. This is also true for the inverse replacement sequence. The BOP link interface can be adapted to the particular unit using the following parameters (refer to Table 3-12).

Table 3-12 BOP link

BOP link – interface

BOP on BOP link

USS on BOP link

No parameter

P2009[1]

r2024[1]

 

P2010[1]

r2025[1]

 

P2011[1]

r2026[1]

 

P2012[1]

r2027[1]

 

P2013[1]

r2028[1]

 

P2014[1]

r2029[1]

 

r2015

r2030[1]

 

P2016

r2031[1]

 

 

r2032

 

 

r2033

Communication modules (CB) such as PROFIBUS, DeviceNet, CANopen and also programming / operator units (e.g. PCs with the DriveMonitor / STARTER start-up software and AOP) as well as programmable controls with communication processor can be connected to the COM link. The plug connector allows the communication modules to be connected to MICROMASTER. On the other hand, the programming / operator units must be connected to the MICROMASTER through terminals 14/15. As for the BOP link, data is transferred between MICROMASTER and the programming / operator unit using the USS protocol. In so doing, for the COM link, the USS protocol is transferred via the bus-capable RS485 interface. Essentially the same as the BOP link, the COM link also automatically defines if a communications module is replaced with a USS unit (PC, AOP). The COM link can be adapted to the particular unit using the following parameters (refer to Table 3-13).

Table 3-13 COM link

COM link – interface

 

CB on COM link

USS on COM link

P2040

 

r2053

P2009[0]

r2024[0]

P2041

 

r2054

P2010[0]

r2025[0]

r2050

 

r2090

P2011[0]

r2026[0]

P2051

 

r2091

P2012[0]

r2027[0]

 

 

 

P2013[0]

r2028[0]

 

 

 

P2014[0]

r2029[0]

 

 

 

r2018

r2030[0]

 

 

 

P2019

r2031[0]

 

 

 

 

r2036

 

 

 

 

r2037

MICROMASTER 420

Operating Instructions

96

6SE6400-5AA00-0BP0

Page 96
Image 96
Siemens 420 manual BOP link interface BOP on BOP link USS on BOP link, COM link interface CB on COM link USS on COM link