Issue 07/04

3 Functions

3.5Commissioning

A differentiation is made between the following scenarios when commissioning

MICROMASTER:

50/60-Hz changeover

Quick commissioning

Motor data identification

Calculating the motor / control data

Series commissioning

Commissioning the application

 

 

 

Commissioning

 

 

 

 

Carry-out checklist

 

 

 

no

NEMA motor

yes

 

 

 

60 Hz / Hp

 

 

 

 

 

50/60 Hz setting

 

 

 

 

Section 3.5.1

 

 

no

Is there a

yes

 

 

complete parameter list

 

 

 

of a commissioning

 

 

Quick commissioning

 

available?

 

 

 

 

 

 

Section 3.5.2

 

 

 

no

Motor weight

yes

 

 

 

?

 

 

 

 

 

P0344 = ?

 

 

 

P0340 = 1

 

 

 

 

 

Series commissioning

 

 

 

 

Section 3.5.6

no

Stator resistance

yes

 

 

 

 

 

 

 

known?

 

 

 

P1910 = 1

 

P0350 = ?

 

ON

 

P0340 = 1

 

A0541

 

 

 

 

 

Application commissioning

 

 

 

 

Section 3.5.5

 

 

 

 

 

 

End of commissioning

 

Fig. 3-14 Procedure when commissioning

MICROMASTER 420

Operating Instructions

6SE6400-5AA00-0BP0

59

Page 59
Image 59
Siemens 420 manual Commissioning, Procedure when commissioning