DC braking

P1232 =...

P1233 =...

DC braking current (entered in %)

100 %

 

Defines level of DC current in [%] relative to rated motor current (P0305).

 

Duration of DC braking (entered in s)

0 s

Defines duration for which DC injection braking is to be active following an OFF1 or OFF3 command.

Compound braking

P1236 =...

Compound braking current (entered in %)

0 %

Defines DC level superimposed on AC waveform after exceeding DC-link voltage threshold of compound braking. The value is entered in [%] relative to rated motor current (P0305). (see also 0).

If P1254 = 0 :

 

Compound braking switch-on level

UDC_Comp = 1.13 2 Vmains = 1.13 2 P0210

otherwise :

 

Compound braking switch-on level

UDC_Comp = 0.98 r1242

Vdc controller

P1240 =...

Configuration of Vdc controller

1

VDC

 

 

Enables / disables Vdc controller.

 

r1242

 

 

0

Vdc controller disabled

 

 

 

 

1

Vdc-max controller enabled

 

 

 

P1254 =...

Auto detect Vdc switch-on levels

1

VDC_max -controller active

t

 

Enables/disables auto-detection of switch-on

A0911

 

levels for Vdc control functionalities.

 

r0056 Bit14 1

 

0

Disabled

 

 

 

1

Enabled

 

0

t

 

 

 

 

f

 

 

 

 

 

 

fact

 

 

 

 

 

fset

 

 

 

 

 

t

PID controller

 

 

 

 

P2200 =...

P2253 =...

P2254 =...

P2257 =...

P2258 =...

P2264 =...

BI: Enable PID controller

0.0

PID mode Allows user to enable/disable the PID controller. Setting to 1 enables the PID controller. Setting 1 automatically disables normal ramp times set in P1120 and P1121 and the normal frequency setpoints

CI: PID setpoint

0.0

Defines setpoint source for PID setpoint input

 

CI: PID trim source

0.0

Selects trim source for PID setpoint. This signal is multiplied by the trim gain and added to the PID setpoint

Ramp-up time for PID setpoint

1.00 s

Sets the ramp-up time for the PID setpoint

 

Ramp-down time for PID setpoint

1.00 s

Sets ramp-down time for PID setpoint

 

 

 

CI: PID feedback

755.0

Selects the source of the PID feedback signal.

 

MICROMASTER 420