Issue 07/04

3 Functions

3.6Inputs / outputs

3.6.1Digital inputs (DIN)

Number:

3 + 1

Parameter range:

r0722 – P0725

Function chart number:

FP2000, FP2200

Features:

 

- cycle time:

2 ms

-switch-on threshold: 10.6 V

-switch-out threshold: 10.6 V

- electrical features:

electrically isolated, short-circuit proof

External control signals are required for a drive converter to be able to operate autonomously. These signals can be entered via a serial interface as well as also via digital inputs (refer to Fig. 3-22). MICROMASTER has 3 digital inputs which can be expanded to a total of 4 by using the 2 analog inputs. The digital inputs, as far as their assignment, can be freely programmed to create a function. Whereby, regarding the program, it is possible to directly assign the function via parameters P0701 - P0704 or to freely program the function using BICO technology.

DIN channel (e.g. DIN1 - PNP (P0725 = 1))

 

 

 

 

 

 

Kl.8

PNP/NPN DIN

 

 

 

 

 

 

 

P24 (PNP)

0 ... 1

 

 

 

 

P0701

 

Kl.9

P0725 (1)

 

 

 

 

 

 

 

0 V (NPN)

 

 

Debounce time: DIN

 

 

 

 

 

 

 

 

 

 

 

 

24 V

 

0 ... 3

 

 

 

 

 

 

 

P0724 (3)

 

 

 

 

0

0

 

 

 

 

 

Function

 

24 V

T

0

 

 

 

 

 

 

 

 

 

 

1

1

 

 

&

r0722

Pxxxx

BI: ...

 

 

 

r0722 .0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO/BO: Bin.inp.val

 

 

 

0 V

 

 

 

 

 

 

DIN channel (e.g. DIN1 - NPN (P0725 = 0))

 

 

 

 

 

 

Kl.8

PNP/NPN DIN

 

 

 

 

 

 

 

P24 (PNP)

0 ... 1

 

 

 

 

P0701

 

Kl.9

P0725 (1)

 

 

 

 

 

 

 

0 V (NPN)

 

 

Debounce time: DIN

 

 

 

 

 

 

 

 

 

 

 

 

24 V

 

0 ... 3

 

 

 

 

 

 

 

P0724 (3)

 

 

 

 

0

0

 

 

 

 

 

Function

 

24 V

T

0

 

 

 

 

 

 

 

 

 

 

1

1

 

 

&

r0722

Pxxxx

BI: ...

 

 

 

r0722 .0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO/BO: Bin.inp.val

 

 

 

0 V

 

 

 

 

 

 

Fig. 3-22

Digital inputs

 

 

 

 

 

 