6F3B0253
198 T1-16S User’s Manual
7. Instructions

FUN 118 SETC Set carry

Expression
Input [ SETC ] Output
Function
When the input is ON, the carry flag (CF = S050) is set to ON.
Execution condition
Input Operation O utput CF
OFF No execution OFF
ON Execution ON Set
Operand
No operand is required.
Example
When R011 is changed from OFF to ON, the carry flag S050 is set to ON.