6F3B0253

7. Instructions

FUN 118

SETC

Set carry

Expression

Input [ SETC ]Output

Function

When the input is ON, the carry flag (CF = S050) is set to ON.

Execution condition

Input

 

Operation

Output

CF

OFF

No execution

 

OFF

ON

Execution

 

ON

Set

Operand

No operand is required.

Example

When R011 is changed from OFF to ON, the carry flag S050 is set to ON.