6F3B0253
228 T1-16S User’s Manual
7. Instructions

FUN 164 AVE Average value

Expression
Input [ A AVE (n) B ] Output
Function
When the input is ON, this instruction calculates the average value of the data stored in the n
registers starting with A, and stores the average value in B. The allowable range of the table size n
is 1 to 64.
Execution condition
Input Operation Output
OFF No execution OFF
ON Execution ON
Operand
Name Device Register Constant Index
X Y R S T. C. XWYWRWSW T C D I J K
AStart of table √√√√√√√
nTable size 1 - 64
BResult √√√√√√√√√
Example
When R012 is ON, the average value of the data stored in the register table D0200 to D0209
(10 words), and the average value is stored in D0520.
D0200 100
D0201 10000
D0202 -1000
D0203 10
D0204 0 D0520 2900 (A verage value)
D0205 200
D0206 -300
D0207 20000
D0208 -30
D0209 20