6F3B0253
|
|
|
| 6. Programming Information |
| ||
|
|
|
|
|
|
| |
| Device/ | Name | Function |
|
| ||
| register |
|
|
|
|
|
|
| S030 | Program error | ON at error state (related to SW06) |
|
| ||
| S031 | Scan time over (down) | ON when the scan time exceeds 200 ms |
|
| ||
| S032 |
| − | Reserved |
|
| |
| S033 |
| − | Reserved |
|
| |
| S034 |
| − | Reserved |
|
| |
| S035 |
| − | Reserved |
|
| |
| S036 |
| − | Reserved |
|
| |
| S037 |
| − | Reserved |
|
| |
| S038 |
| − | Reserved |
|
| |
| S039 |
| − | Reserved |
|
| |
| S03A |
| − | Reserved |
|
| |
| S03B |
| − | Reserved |
|
| |
| S03C |
| − | Reserved |
|
| |
| S03D |
| − | Reserved |
|
| |
| S03E |
| − | Reserved |
|
| |
| S03F |
| − | Reserved |
|
| |
| S040 | Timing relay | 0.1 s | OFF 0.05 s / ON 0.05 s (0.1 s interval) |
|
|
|
| S041 | Timing relay | 0.2 s | OFF 0.1 s / ON 0.1 s (0.2 s interval) |
|
|
|
| S042 | Timing relay | 0.4 s | OFF 0.2 s / ON 0.2 s (0.4 s interval) |
| All OFF at the |
|
| S043 | Timing relay | 0.8 s | OFF 0.4 s / ON 0.4 s (0.8 s interval) |
| beginning of |
|
| S044 | Timing relay 1.0 s | OFF 0.5 s / ON 0.5 s (1.0 s interval) |
| RUN mode |
| |
| S045 | Timing relay | 2.0 s | OFF 1.0 s / ON 1.0 s (2.0 s interval) |
|
|
|
| S046 | Timing relay | 4.0 s | OFF 2.0 s / ON 2.0 s (4.0 s interval) |
|
|
|
| S047 | Timing relay | 8.0 s | OFF 4.0 s / ON 4.0 s (8.0 s interval) |
|
|
|
| S048 |
| − | Reserved |
|
| |
| S049 |
| − | Reserved |
|
| |
| S04A |
| − | Reserved |
|
| |
| S04B |
| − | Reserved |
|
| |
| S04C |
| − | Reserved |
|
| |
| S04D |
| − | Reserved |
|
| |
| S04E | Always OFF |
| Always OFF |
|
| |
| S04F | Always ON |
| Always ON |
|
|
NOTE | (1) These devices are set by the |
| |
| are read only for user. |
(2)Devices marked as (down) are set in the ERROR mode. Therefore these devices cannot be used in the user program.
Basic Hardware and Function 81