WARNING

 

Before troubleshooting or repair work, check the earth wire is connected to the earth

 

terminals of the main unit, otherwise an electric shock is caused when a leak occurs.

Check earth wires.

If the earth wire is not correctly connected, contact an electric engineer for rework.

 

 

 

 

Do not modify the products.

 

Do not also disassemble or modify the parts. It may cause a fire, electric shock or injury.

Prohibition of modification.

 

 

 

 

For spare parts, use those specified ().

 

If unspecified parts are used, a fire or electric shock may be caused.

Use specified parts.

: For details, refer to the parts list.

 

 

 

Before troubleshooting or repair work, do not bring a third party (a child, etc.) except

 

the repair engineers close to the equipment.

Do not bring a child

It causes an injury with tools or disassembled parts.

Please inform the users so that the third party (a child, etc.) does not approach the equipment.

close to the equipment.

 

 

 

Connect the cut-off lead cables with crimp contact, etc, put the closed end side

 

upward and then apply a water-cut method, otherwise a leak or production of fire is

 

caused at the users’ side.

Insulating measures

 

When repairing the refrigerating cycle, take the following measures.

1)Be attentive to fire around the cycle. When using a gas stove, etc, be sure to put out fire before work; otherwise the oil mixed with refrigerant gas may catch fire.

 

2) Do not use a welder in the closed room. When using it without ventilation, carbon

No fire

monoxide poisoning may be caused.

3)Do not bring inflammables close to the refrigerant cycle, otherwise fire of the welder may catch the inflammables.

Check the used refrigerant name and use tools and materials of the parts which match with it.

For the products which use R410A refrigerant, the refrigerant name is indicated at a position on the outdoor unit where is easy to see. To prevent miss-charging, the route of the service port is changed from one of the former R22.

 

For an air conditioner which uses R410A, never use other refrigerant than R410A.

 

For an air conditioner which uses other refrigerant (R22, etc.), never use R410A.

 

If different types of refrigerant are mixed, abnormal high pressure generates in the refriger-

 

ating cycle and an injury due to breakage may be caused.

 

Do not charge refrigerant additionally.

 

If charging refrigerant additionally when refrigerant gas leaks, the refrigerant composition in

 

the refrigerating cycle changes resulted in change of air conditioner characteristics or

 

refrigerant over the specified standard amount is charged and an abnormal high pressure is

 

applied to the inside of the refrigerating cycle resulted in cause of breakage or injury.

 

Therefore if the refrigerant gas leaks, recover the refrigerant in the air conditioner, execute

Refrigerant

vacuuming, and then newly recharge the specified amount of liquid refrigerant. In this time,

 

never charge the refrigerant over the specified amount.

 

When recharging the refrigerant in the refrigerating cycle, do not mix the refrigerant

 

or air other than R410A into the specified refrigerant.

 

If air or others is mixed with the refrigerant, abnormal high pressure generates in the

 

refrigerating cycle resulted in cause of injury due to breakage.

 

After installation work, check the refrigerant gas does not leak.

 

If the refrigerant gas leaks in the room, poisonous gas generates when gas touches to fire

 

such as fan heater, stove or cocking stove though the refrigerant gas itself is innocuous.

 

Never recover the refrigerant into the outdoor unit.

 

When the equipment is moved or repaired, be sure to recover the refrigerant with recover-

 

ing device. The refrigerant cannot be recovered in the outdoor unit; otherwise a serious

 

accident such as breakage or injury is caused.

 

 

 

After repair work, surely assemble the disassembled parts, and connect and lead the

 

removed cables as before. Perform the work so that the cabinet or panel does not

 

catch the inner cables.

Assembly/Cabling

If incorrect assembly or incorrect cable connection was done, a disaster such as a leak or

fire is caused at user’s side.

 

– 5 –

Page 5
Image 5
Toshiba RAV-SM1402BT-E Do not modify the products, For spare parts, use those specified ∗, Caused at the users’ side

RAV-SP1102UT-E, RAV-SM562BT-E, RAV-SM562CT-E, RAV-SM563AT-E, RAV-SM802BT-E specifications

Toshiba, a prominent player in the HVAC sector, has engineered a range of advanced air conditioning systems that cater to diverse environments and needs. Among their standout offerings are the RAV-SM562BT-E, RAV-SM1102CT-E, RAV-SM563AT-E, RAV-SM1403UT-E, and RAV-SM803UT-E models. Each of these systems embodies Toshiba's commitment to energy efficiency, innovative technology, and user-centric design.

The RAV-SM562BT-E model is designed for residential and light commercial use, boasting a cooling capacity of 5.6 kW and a heating capacity of 6.7 kW. It incorporates Toshiba’s advanced inverter technology, ensuring optimal performance and reduced energy consumption. The unit features a sleek, modern design and operates quietly, making it perfect for environments where noise levels must be controlled.

Next in line is the RAV-SM1102CT-E, which excels in larger commercial spaces. With a remarkable cooling output of 11.2 kW and heating performance to match, this unit is engineered for heavy-duty usage. It employs a multi-split system, allowing several indoor units to connect to a single outdoor unit. This provides homes or businesses with flexible installation options without sacrificing comfort or style.

The RAV-SM563AT-E model presents a perfect blend of efficiency and effectiveness, focusing on eco-friendliness. With an impressive seasonal energy efficiency ratio (SEER), it minimizes energy bills while maintaining superior performance. This model is equipped with advanced filtration technology that not only cools or heats the air but also improves indoor air quality by capturing dust and allergens.

Designed for high-performance requirements, the RAV-SM1403UT-E offers cooling and heating capacities of 14.0 kW. This unit is hardy enough for industrial applications but remains efficient and easy to operate. The incorporation of Toshiba’s Smart Control technology allows users to manage their systems remotely, enhancing convenience.

The RAV-SM803UT-E completes the lineup, combining 8.0 kW cooling and heating outputs with cutting-edge technology. It features adaptive comfort control, which adjusts the temperature based on occupancy and external conditions, ensuring optimal comfort while maintaining energy efficiency.

In conclusion, Toshiba's range of RAV-SM series models offers innovative features, advanced technology, and effective performance. These models not only meet the demands of modern spaces but also shine in energy efficiency, making them excellent choices for both residential and commercial applications. By addressing the diverse requirements of users, Toshiba continues to uphold its reputation as a leader in HVAC solutions.