Toshiba RAV-SM802BT-E, RAV-SM1102CT-E, RAV-SM1102BT-E Indoor unit, Outdoor unit, Height difference

Models: RAV-SP1102UT-E RAV-SM562BT-E RAV-SM562CT-E RAV-SM563AT-E RAV-SM802BT-E RAV-SM802CT-E RAV-SM803UT-E RAV-SM803AT-E RAV-SM1402BT-E RAV-SM1103UT-E RAV-SM1402CT-E RAV-SM1403UT-E RAV-SM1102BT-E RAV-SM1102CT-E

1 195
Download 195 pages 37.15 Kb
Page 37
Image 37

RAV-SP1102UT-E, RAV-SM1102BT-E, RAV-SM1102CT-E / RAV-SP1102AT-E

Outer diameter of refrigerant pipe

Gas side ØA

Liquid side ØB

 

 

15.9mm

9.5mm

 

 

 

Height difference (m)

 

 

Outdoor unit

Outdoor unit

at upper side

at lower side

 

 

30

15

 

 

Indoor unit

TCJ sensor

Distributor

(Strainer incorporated)

Strainer

 

Air heat exchanger

 

 

TC sensor

*The refrigerating cycle of the indoor units differs according to the models to be combined. For the refrigerating cycles of the other indoor units, refer to the corresponding Service Manuals described in the list on the cover.

 

Refrigerant pipe at gas side

Refrigerant pipe at liquid side

 

Height difference

Outer dia. Ø A

 

Outer dia. Ø B

 

 

Section shape

 

 

 

 

of heat insulator

 

 

 

 

 

 

Min.

Max.

 

 

 

 

5m

70m

 

Ball valve

 

 

Packed valve

 

 

Outer dia. Ø A

Outdoor unit

Outer dia. Ø B

 

 

Strainer

 

 

 

 

 

PMV

 

TS sensor

Check joint

 

 

 

 

 

(UKV-25D22)

 

 

 

 

 

 

 

TO sensor

 

 

 

 

TD sensor

 

 

 

 

 

 

 

TE sensor

 

Strainer

 

 

 

 

 

 

4-way valve

 

 

 

 

(STF-0401G)

 

 

 

 

 

Heat exchanger

 

Distributor

 

Muffler

2 row 52 stages

 

 

 

 

 

 

 

 

 

 

 

 

Outside :

 

 

 

 

 

 

 

 

 

Ø 25 ×

L210

Ø 8 FP1.3 flat fin

 

 

 

 

 

Accumulator

 

Inside :

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2500cc)

Rotary

Ø 25 ×

L180

Ø 9.52 FP1.5 flat fin

 

 

 

 

 

 

 

compressor

 

 

 

 

 

 

 

 

 

 

(DA420A3F – 21M)

 

 

 

 

 

R410A 2.95kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

Heating

 

 

 

Pressure

 

Pipe surface temperature (°C)

Compressor

 

Indoor/Outdoor

 

 

 

 

 

 

 

 

 

Indoor

temp. conditions

 

 

 

(MPa)

 

 

 

Indoor heat

Outdoor heat

revolutions per

 

 

 

Discharge

Suction

(DB/WB) (°C)

 

 

 

fan

 

 

 

second (rps)

 

 

 

 

exchanger

exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pd

Ps

(TD)

(TS)

(TC)

(TE)

*

 

Indoor

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard

2.55

0.98

69

12

10

40

40

HIGH

27/19

35/–

Cooling

Overload

3.28

1.08

82

17

16

48

50

HIGH

32/24

43/–

 

Low load

1.76

0.76

47

8

5

27

24

LOW

18/15.5

–5/–

 

Standard

2.58

0.73

68

3

40

3

44

HIGH

20/–

7/6

Heating

Overload

3.43

1.18

75

20

56

16

24

LOW

30/–

24/18

 

Low load

2.10

0.32

88

–14

34

–13

63

HIGH

15/–

–15/(70%)

* 4 poles are provided to this compressor.

The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.

– 37 –

Page 37
Image 37
Toshiba RAV-SM802BT-E Indoor unit, Outdoor unit, RAV-SP1102UT-E, RAV-SM1102BT-E, RAV-SM1102CT-E / RAV-SP1102AT-E