SAFETY CAUTION

The important contents concerned to the safety are described on the product itself and on this Service Manual.

Please read this Service Manual after understanding the described items thoroughly in the following contents (Indications/Illustrated marks), and keep them.

[Explanation of indications]

Indication

Explanation

 

 

DANGER

Indicates contents assumed that an imminent danger causing a death or serious injury of

the repair engineers and the third parties when an incorrect work has been executed.

 

 

WARNING

Indicates possibilities assumed that a danger causing a death or serious injury of the

repair engineers, the third parties, and the users due to troubles of the product after work

 

when an incorrect work has been executed.

 

 

CAUTION

Indicates contents assumed that an injury or property damage () may be caused on the

repair engineers, the third parties, and the users due to troubles of the product after work

 

when an incorrect work has been executed.

 

 

Property damage : Enlarged damage concerned to property, furniture, and domestic animal/pet

[Explanation of illustrated marks]

Mark

Explanation

Indicates prohibited items (Forbidden items to do)

The sentences near an illustrated mark describe the concrete prohibited contents.

Indicates mandatory items (Compulsory items to do)

The sentences near an illustrated mark describe the concrete mandatory contents.

Indicates cautions (Including danger/warning)

The sentences or illustration near or in an illustrated mark describe the concrete cautious contents.

[Confirmation of warning label on the main unit]

Confirm that labels are indicated on the specified positions (Refer to the Parts disassembly diagram (Outdoor unit).)

If removing the label during parts replace, stick it as the original.

DANGER

 

Turn “OFF” the breaker before removing the front panel and cabinet, otherwise an electric

 

shock is caused by high voltage resulted in a death or injury.

 

During operation, a high voltage with 400V or higher of circuit () at secondary circuit of the high-

 

voltage transformer is applied.

Turn off breaker.

If touching a high voltage with the naked hands or body, an electric shock is caused even if using an

electric insulator.

 

 

: For details, refer to the electric wiring diagram.

When removing the front panel or cabinet, execute short-circuit and discharge between high- voltage capacitor terminals.

Execute discharge

If discharge is not executed, an electric shock is caused by high voltage resulted in a death or injury.

After turning off the breaker, high voltage also keeps to apply to the high-voltage capacitor.

between terminals.

 

Do not turn on the breaker under condition that the front panel and cabinet are removed.

An electric shock is caused by high voltage resulted in a death or injury.

Prohibition

– 4 –

Page 4
Image 4
Toshiba RAV-SM1103UT-E, RAV-SM803AT-E Explanation of indications, Explanation of illustrated marks, Indication Explanation

RAV-SP1102UT-E, RAV-SM562BT-E, RAV-SM562CT-E, RAV-SM563AT-E, RAV-SM802BT-E specifications

Toshiba, a prominent player in the HVAC sector, has engineered a range of advanced air conditioning systems that cater to diverse environments and needs. Among their standout offerings are the RAV-SM562BT-E, RAV-SM1102CT-E, RAV-SM563AT-E, RAV-SM1403UT-E, and RAV-SM803UT-E models. Each of these systems embodies Toshiba's commitment to energy efficiency, innovative technology, and user-centric design.

The RAV-SM562BT-E model is designed for residential and light commercial use, boasting a cooling capacity of 5.6 kW and a heating capacity of 6.7 kW. It incorporates Toshiba’s advanced inverter technology, ensuring optimal performance and reduced energy consumption. The unit features a sleek, modern design and operates quietly, making it perfect for environments where noise levels must be controlled.

Next in line is the RAV-SM1102CT-E, which excels in larger commercial spaces. With a remarkable cooling output of 11.2 kW and heating performance to match, this unit is engineered for heavy-duty usage. It employs a multi-split system, allowing several indoor units to connect to a single outdoor unit. This provides homes or businesses with flexible installation options without sacrificing comfort or style.

The RAV-SM563AT-E model presents a perfect blend of efficiency and effectiveness, focusing on eco-friendliness. With an impressive seasonal energy efficiency ratio (SEER), it minimizes energy bills while maintaining superior performance. This model is equipped with advanced filtration technology that not only cools or heats the air but also improves indoor air quality by capturing dust and allergens.

Designed for high-performance requirements, the RAV-SM1403UT-E offers cooling and heating capacities of 14.0 kW. This unit is hardy enough for industrial applications but remains efficient and easy to operate. The incorporation of Toshiba’s Smart Control technology allows users to manage their systems remotely, enhancing convenience.

The RAV-SM803UT-E completes the lineup, combining 8.0 kW cooling and heating outputs with cutting-edge technology. It features adaptive comfort control, which adjusts the temperature based on occupancy and external conditions, ensuring optimal comfort while maintaining energy efficiency.

In conclusion, Toshiba's range of RAV-SM series models offers innovative features, advanced technology, and effective performance. These models not only meet the demands of modern spaces but also shine in energy efficiency, making them excellent choices for both residential and commercial applications. By addressing the diverse requirements of users, Toshiba continues to uphold its reputation as a leader in HVAC solutions.