No.

Item

Outline of specifications

Remarks

 

 

 

 

17

Max. frequency 1)

This control is operated by selecting [AUTO] operation

 

 

cut control

mode.

 

 

2)

COOL operation mode: the frequency is controlled

 

 

 

according to the following figure if To < 28°C.

 

Ta(˚C)+4 Normal control

Max. frequency is restricted

+3to approximately the rated cooling frequency

Tsc

3)HEAT operation mode: the frequency is controlled according to the following figure if To > 15°C.

It cannot be operated on the remote controller at indoor unit side. (Stop status is held.)

 

Ta(˚C)

 

 

 

 

 

Tsh

 

 

 

 

 

 

 

Max. frequency is restricted

 

 

 

 

 

–3

 

 

to approximately the rated

 

 

 

 

 

 

heating frequency

 

–4

 

 

 

 

 

Normal control

 

 

18 DC motor

1) When the fan operation has started, positioning of the

 

stator and the rotor are performed.

 

(Moves slightly with tap sound)

2)The motor operates according to the command from the indoor controller.

NOTES :

When the fan rotates while the air conditioner stops due to entering of outside air, etc, the air conditioner may oper- ated while the fan motor stops.

• When a fan locking is found, the air conditioner stops, and Check code [P12] an error is displayed.

– 69 –