No.

Item

 

Outline of specifications

 

Remarks

 

 

 

 

 

 

 

14

Central control

1)

Setting at the central controller side enables to select

 

 

 

 

mode selection

 

the contents which can be operated on the remote

 

 

 

 

 

 

controller at indoor unit side.

 

 

 

 

 

2)

RBC-AMT31E

 

 

 

 

 

 

[Last push priority] :

(No display)

 

 

 

The operation contents can be selected from both

 

 

 

 

 

 

remote controller and central controller of the indoor

 

 

 

 

 

 

unit side, and the operation is performed with the

 

 

 

 

 

 

contents selected at the last.

 

 

 

 

 

 

[Center] :

[CENTER] goes on.

 

 

 

Start/Stop operation only can be handled on the remote

 

 

 

 

 

 

controller at indoor unit side.

 

 

 

 

 

 

[Operation Prohibited] :

[CENTER] goes on.

 

 

 

It cannot be operated on the remote controller at indoor

In a case of wireless type, the

 

 

 

unit side. (Stop status is held.)

display lamp does not change.

 

 

 

 

 

However, contents which can

 

 

 

 

 

be operated are same.

 

 

 

 

 

The status set in [CENTER]/

 

 

 

 

 

[Operation Prohibited] mode is

 

 

 

 

 

notified with the receiving sound

 

 

 

 

 

“Pi, Pi, Pi, Pi, Pi” (5 times).

 

 

 

 

 

 

 

15

Energy-save

1)

Selecting [AUTO] mode enables an energy-saving to be

 

 

 

 

control

 

operated.

 

 

 

 

(By connected

2)

The setup temperature is shifted (corrected) in the

 

 

 

 

outdoor unit)

 

range not to lose the comfort ability according to input

 

 

 

 

 

 

values of various sensors.

 

 

 

 

 

3) Data (Input value room temp. Ta, Outside temp. To, Air

 

 

 

 

 

 

volume, Indoor heat exchanger sensor temp. Tc) for 20

 

 

 

 

 

 

minutes are taken the average to calculate correction

 

 

 

 

 

 

value of the setup temperature.

 

 

 

 

 

4)

The setup temperature is shifted every 20 minutes, and

 

 

 

 

 

 

the shifted range is as follows.

 

 

 

 

 

 

In cooling time : +1.5 to –1.0K

 

 

 

 

 

 

In heating time : –1.5 to +1.0K

 

 

 

 

 

 

 

 

 

16

Louver control

The louver angle is displayed setting 0° as “Full close”.

 

 

 

 

Full close

 

 

1) Louver

 

 

 

 

 

 

 

 

 

 

 

 

 

position

 

 

 

 

 

 

 

 

1)

In the initial operation after power-ON, the position is

 

 

 

 

 

 

automatically controlled according to the operating

 

 

 

 

 

status (COOL/HEAT).

 

 

 

 

 

 

 

Cooling

Heating

 

 

 

 

45˚

103˚

2)After then a louver position is stored in the microcomputer every time when position is operated on the remote controller, and the louver operates at the position stored in memory in the next operation and after.

*If the operation mode has been changed from COOL to HEAT, from HEAT to COOL, or the power has turned off, the stored louver position is cleared and the status returns to one in item 1).

2) Air direction

1)

When pushing [LOUVER] button during operation, the louver starts swinging.

adjustment

2)

When the louver has arrived at the desired position, push [LOUVER] again.

(Swing

 

The louver stops at that position.

operation)

 

 

– 68 –