Compressor

 

 

 

 

 

CM

1 1

RED

P04

 

 

2 2

WHI

P05

Q200~205

P.C. Board

 

3 3

BLK

P06

IGBT

 

 

 

 

R221

(MCC-5009)

 

 

 

 

 

 

YEL

P25

 

 

 

 

 

P24

 

R220

 

 

 

 

 

 

 

YEL

P23

 

 

 

 

 

P22

 

R219

 

 

 

 

 

 

 

BRN

P21

 

 

F03

CAUTION : HIGH VOLTAGE

 

P20

 

 

Q300~305

MOS-FET

R321

R320

R319

CN300

CN700

3

3

BLK

 

2

2

WHI

FM

1

1

RED

 

 

 

 

Fan motor

6

6

 

 

5

5

 

 

4

4

 

PMV

3

3

 

 

 

2

2

 

 

1

1

 

Pulse motor valve

 

 

 

RAV-

5-2.

SM563AT-E, RAV-SM803AT

Outdoor Unit (Wiring

– 42 –

 

YEL

P35

 

L03

C13

Fuse

The high voltage circuit is

 

 

 

 

T3.15A

incorporated.

 

P34

DB01

 

 

 

AC250V

 

 

 

 

 

Be careful to do the check service,

 

 

 

 

 

 

 

 

 

 

 

 

 

as the electric shock may be

 

 

 

 

 

 

 

caused in case of touching

 

 

 

 

C12

C14

 

parts on the

 

 

 

 

 

 

 

 

 

 

 

 

P.C. board by hand

 

 

Power

 

 

 

 

 

 

 

relay

 

 

 

 

The 4-way valve coil is turned on

 

P19

DB02

CT

 

 

 

while the cooling operation

ORN

 

 

 

 

 

 

 

 

 

 

 

 

 

P18

 

 

 

 

 

 

2 2

P11

 

Relay

 

 

 

 

 

 

 

 

 

Reactor

1 1

P08

 

 

 

 

 

NOTE

 

 

Q404

 

 

 

 

CM

: Compressor

 

 

 

P33

P32

 

CN701

 

 

PMV

: Pulse motor valve

1

2

3

CN605

 

P31

P30

1

3

FM

: Fan motor

1

2

3

BLK

 

 

2 1

1

3

TE

: Heat exchanger Temp. Sensor

RED WHI BLK

 

PUR

 

2 1

 

 

 

 

 

 

 

 

 

TD

: Discharge Temp. Sensor

1

2

3

 

 

 

 

 

 

TO

: Outdoor Temp. Sensor

 

 

 

 

 

 

1

2

3

 

 

 

 

 

 

TS

: Suction Temp. Sensor

 

 

 

 

 

 

SW802

 

 

 

 

 

 

 

IGBT

: Insulated Gate Bipolar Transistor

 

 

 

 

 

Reactor

 

 

DB

: Rectifier

MCC-1530

 

 

 

 

 

CT

: Curreut Transformer

Sub P.C. Board

 

 

 

 

 

Color Identification

BLK

: BLACK

WHI :

WHITE

BLU

: BLUE

BRN :

BROWN

RED

: RED

ORN :

ORANGE

GRY

: GRAY

YEL :

YELLOW

PNK

: PINK

PUR :

PURPLE

L01

Varistor

3

3

 

 

 

 

2

 

 

CN603

1

1

Surge

 

 

 

TS

 

 

 

(Suction pipe

absorber

 

2

2

temp. sensor)

 

 

 

 

CN602

1

1

 

Varistor

 

 

 

TO

 

 

 

 

(Outdoor

 

 

3

3

temp. sensor)

 

 

 

 

 

2

 

 

F01

CN601

1

1

 

Fuse

 

 

 

TD

T25A

 

 

 

(Discharge pipe

AC250V

 

2

2

temp. sensor)

 

 

 

CN600

1

1

 

 

P03

P10

P02

 

TE

 

 

(Condenser pipe

P7

ORN

BLK

WHI CN806

 

temp. sensor)

 

 

 

 

 

 

 

BLK

 

ORN

BLK

WHI

1 2 3 4 5

 

 

For optional P.C. Board

Coil for

Reactor

 

 

 

4-WAY

 

 

 

 

 

 

 

 

VALVE

 

 

 

 

 

Fuse 250V~

 

 

 

GRN/YEL

WHI

RED

WHI

 

T6.3A

RED

 

 

 

 

 

1 2 3 L N

To indoor

Power supply

 

220-240V~ 50Hz

-E

Diagram)

Page 42
Image 42
Toshiba RAV-SM1102CT-E, RAV-SM1102BT-E, RAV-SM1403UT-E, RAV-SM1402CT-E MCC-5009, Outdoor Unit Wiring, Diagram, Board

RAV-SP1102UT-E, RAV-SM562BT-E, RAV-SM562CT-E, RAV-SM563AT-E, RAV-SM802BT-E specifications

Toshiba, a prominent player in the HVAC sector, has engineered a range of advanced air conditioning systems that cater to diverse environments and needs. Among their standout offerings are the RAV-SM562BT-E, RAV-SM1102CT-E, RAV-SM563AT-E, RAV-SM1403UT-E, and RAV-SM803UT-E models. Each of these systems embodies Toshiba's commitment to energy efficiency, innovative technology, and user-centric design.

The RAV-SM562BT-E model is designed for residential and light commercial use, boasting a cooling capacity of 5.6 kW and a heating capacity of 6.7 kW. It incorporates Toshiba’s advanced inverter technology, ensuring optimal performance and reduced energy consumption. The unit features a sleek, modern design and operates quietly, making it perfect for environments where noise levels must be controlled.

Next in line is the RAV-SM1102CT-E, which excels in larger commercial spaces. With a remarkable cooling output of 11.2 kW and heating performance to match, this unit is engineered for heavy-duty usage. It employs a multi-split system, allowing several indoor units to connect to a single outdoor unit. This provides homes or businesses with flexible installation options without sacrificing comfort or style.

The RAV-SM563AT-E model presents a perfect blend of efficiency and effectiveness, focusing on eco-friendliness. With an impressive seasonal energy efficiency ratio (SEER), it minimizes energy bills while maintaining superior performance. This model is equipped with advanced filtration technology that not only cools or heats the air but also improves indoor air quality by capturing dust and allergens.

Designed for high-performance requirements, the RAV-SM1403UT-E offers cooling and heating capacities of 14.0 kW. This unit is hardy enough for industrial applications but remains efficient and easy to operate. The incorporation of Toshiba’s Smart Control technology allows users to manage their systems remotely, enhancing convenience.

The RAV-SM803UT-E completes the lineup, combining 8.0 kW cooling and heating outputs with cutting-edge technology. It features adaptive comfort control, which adjusts the temperature based on occupancy and external conditions, ensuring optimal comfort while maintaining energy efficiency.

In conclusion, Toshiba's range of RAV-SM series models offers innovative features, advanced technology, and effective performance. These models not only meet the demands of modern spaces but also shine in energy efficiency, making them excellent choices for both residential and commercial applications. By addressing the diverse requirements of users, Toshiba continues to uphold its reputation as a leader in HVAC solutions.