Toshiba RAV-SM562BT-E Revised Mar, L29 error, H02 error, IPDU P.C. board error Defect ÆReplace

Models: RAV-SP1102UT-E RAV-SM562BT-E RAV-SM562CT-E RAV-SM563AT-E RAV-SM802BT-E RAV-SM802CT-E RAV-SM803UT-E RAV-SM803AT-E RAV-SM1402BT-E RAV-SM1103UT-E RAV-SM1402CT-E RAV-SM1403UT-E RAV-SM1102BT-E RAV-SM1102CT-E

1 195
Download 195 pages 37.15 Kb
Page 96
Image 96

Revised : Mar. 2007

[L29 error]

Are connections of

NO

CDB CN800 and CDB IPDU CN06

 

 

connectors normal?

 

 

YES

 

 

 

 

 

 

Correct connection of connector.

Was the error just after power ON determined?

NO

Is there no abnormal overload?

NO

YES

Are cabling/connector normal?

NO

 

 

 

 

 

 

YES

 

 

 

 

 

 

YES

Check cabling between IPDU and CDB and connector.

IPDU P.C. board error

Defect ÆReplace

Improve and eliminate the cause.

Is IPDU P.C. board come to

NO

 

closely contact with heat sink?

 

 

YES

 

 

 

 

 

 

Correct mounting.

IPDU P.C. board error Defect ÆReplace

[H02 error]

NO

Is power voltage normal?

 

YES

 

 

 

 

 

 

NO

 

 

 

Are connections of

 

 

 

 

 

 

 

cable/connector normal?

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

NO

Is compressor normal?

Is there no

 

 

 

slackened refrigerant?

 

 

 

 

 

 

YES

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

Does electron expansion

 

 

 

 

 

 

 

valve normally operate?

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

Improve power line.

Check and correct circuit cabling such as cabling to compressor

(phase missing) and connector.

Compressor lock ÆReplace

Check TE and TS sensors. ÆReplace Check electron expansion valve. ÆReplace

Check IPDU and CDB. Defect ÆReplace

*For RAV-SM563AT-E, SM803AT-E, replace control P.C. board.