Table 13-1 MACHine Subsystem Parameter Values
Parameter Value
arm_source {RUN | INTermodule | MA CHine {1|2}}
pod_list {NONE | <pod_num>[ , <pod_num>]...}
pod_num integer from 1 to 8
arm_level integer from 1 to 11 representing sequence level
machine_name string of up to 10 alphanumeric characters
res_id {<state_terms>|H|J} for state analyzer
or
{<state_terms>|EDGE{1|2}} for timing analyzer
new_text string of up to 8 alphanumeric characters
state_terms {A|B|C|D|E|F|G|I| RANGE{1|2}|TIM ER {1|2}}
res_terms {<res_id>[,<res_id>]...}
MACHine
Selector :MACHine<N>
The MACHine <N> selector specifies which of the two analyzers (machines)
available in the Agilent 1670G-series logic analyzer which the commands or
queries will refer to. Because the MACHine<N> command is a root level
command, it will normally appear as the first element of a compound header.
<N> {1|2} (the machine number)
Example OUTPUT XXX; ":MACH INE1:NAME ’TIMIN G’"
MACHine Subsystem
MACHine
13–4