TCONtrol
Command :MACHine{1|2}:STRigger:TCONtrol<N> <timer_num>,

{OFF|STARt|PAUSe|CONTinue}

The TCONtrol (timer control) command allows you to turn off, start, pause,
or continue the timer for the specified level. The time value of the timer is
defined by the TIMER command. There are two timers and they are available
for either machine but not both machines simultaneously.
<N> integer from 1 to the number of existing sequence levels (maximum 12)
<timer_num> {1|2}
Example OUTPUT XXX;":MACHINE2:STRIGGER:TCONTROL6 1, PAUSE"
Query :MACHine{1|2}:STRigger:T CONTROL<N>? <tim er_num>
The TCONtrol query returns the current TCONtrol setting of the specified
level.
Returned Format [:MACHine{1|2}:S TR igger:TCONTROL<N> <t imer_num>]
{OFF|STARt|PAUSe|CONTinue}<NL>
Example OUTPUT XXX;":MACHINE2:STRIGGER:TCONTROL6? 1"
STRigger (STRace) Subsystem
TCONtrol
16–20