OVERView:HIGH
Command :SPA{1|2}:OV ERView:HIGH <hig h_pattern>
The OVERView:HIGH command sets the upper boundary of the State
Overview measurement. A query returns the current setting of the upper
boundary.
Setting the upper boundary defaults the data accumulators, statistic
counters, and the number of buckets and their size.
<high_pattern> "{#B{0|1}...|
#Q{0|1|2|3|4|5|6|7}...|
#H{0|1|2|3|4|5|6|7|8|9|A|B|C|D|E|F}.. .|
{0|1|2|3|4|5|6|7|8|9}...}"
Example OUTPUT XXX;":SPA1 :OVERView:HIGH ’ 23394’"
OUTPUT XXX;":SP A2:OVERView:HIGH ’#Q4371’"
Query :SPA{1|2}:OVERView:HIGH?
Returned Format [:SPA{1|2}:OVERView:HIGH ]<high_pattern><NL>
Example 10 DIM String$[100]
20 OUTPUT XXX;":SELECT 1"
30 OUTPUT XXX;":SPA1:OVERView:HIGH?"
40 ENTER XXX;String $
50 PRINT String$
60 END
SPA Subsystem
OVERView:HIGH
25–9