OCONdition
Command :MACHine{1|2}:TLISt:OCONdition {ENTering|EXITing}
The OCONdition command specifies where the O marker is placed. The O
marker can be placed on the entry or exit point of the OPATtern when in the
PATTern marker mode.
Example OUTPUT XXX; ":MACHINE1:TLIST:OCONDITION ENTERING"
Query :MACHine{1|2}:TLISt:OCONdition?
The OCONdition query returns the current setting.
Returned Format [:MACHine{1|2}:TLISt:OCONdition] {ENTering|EXITing}<NL>
Example OUTPUT XXX;":MACHIN E1:TLIST:OCONDIT ION?"
TLISt Subsystem
OCONdition
24–11