OFFSet
Command :CHANnel<N>:OFFSet <value>
The OFFSet command sets the voltage that is represented at center screen
for the selected channel. The allowable offset voltage values are shown in
the table below. The table represents values for a Probe setting of 1:1. The
offset value is recompensated whenever the probe attenuation factor is
changed.
<N> {1|2}
<value> allowable offset voltage value shown in the table below.
Vertical Range Offset Voltage
16 mV - 400 mV ±2 V
>400 mV - 1.6 V ±10 V
>1.6 V - 10 V ±50 V
>10 V - 40 V ±250 V
Example OUTPUT XXX;":CHAN1:OFFS 1.5"
Query :CHANnel<N>:OFFSet?
The OFFSet query returns the current value for the selected channel.
Returned Format [:CHANnel<N>:OFFSet] <value><NL>
Example OUTPUT XXX;":CHANNEL1:OFFSET?"
CHANnel Subsystem
OFFSet
30-6