FIND
Command :MACHine{1|2}:TTRigger:FIND<N>
<time_qualifier>,<condition_mode>
The FIND command defines the qualifier for a given sequence level. The
qualifier tells the timing analyzer when to proceed to the next sequence level.
When this proceed qualifier is matched for either the specified time or
occurrence, the trigger sequence will proceed to the next sequence level. In
the sequence level where the trigger is specified, the FIND command
specifies the trigger qualifier (see SEQuence command).
The terms A through G and I are defined by the TERM command. The
meaning of IN_RANGE and OUT_RANGE is determined by the RANGe
command. Expressions are limited to what you could manually enter through
the Timing Trigger menu. Regarding parentheses, the syntax definitions
below show only the required ones. Additional parentheses are allowed as
long as the meaning of the expression is not changed. See figure 22-2 on
page 22-11 for a detailed example.
<N> integer from 1 to the number of existing sequence levels (maximum 10)
<condition_
mode> {{GT|LT}, <duration_time>|OCCurrence, <occurrence>}
GT greater than
LT less than
<duration_
time> real number from 8 ns to 5.00 seconds depending on sample period
<occurrence> integer from 1 to 1048575
<time_
qualifier> <qualifier> see "Qualifier" on page 22-6
TTRigger (TTRace) Subsystem
FIND
22–14